Retrospective comparison of the effects of laryngeal mask and endotracheal tube on some cardio-respiratory variables in pet rabbits undergoing anaesthesia for elective gonadectomy

Author:

Bellini Luca,Schrank Magdalena,Veladiano Irene Alessandra,Contiero Barbara,Mollo Antonio

Abstract

Abstract Background Endotracheal intubation in rabbits is challenging and supraglottic airway devices, such as laryngeal masks (LMA), represent an alternative as they are easy to insert, and do not stimulate the larynx requiring therefore a lighter plane of anaesthesia for their insertion and positioning than the endotracheal tubes. We investigated whether, compared to an endotracheal tube, the LMA can reduce the negative effects of general anaesthetics on some cardiovascular and respiratory parameters routinely monitored in rabbits anaesthetized for elective gonadectomy. The records of 21 adult mixed breed pet rabbits were collected retrospectively. Rabbits were divided in two groups based on the type of airway device used. A laryngeal mask secured the airway in group LMA (n = 11), and in group ETT (n = 10) an endotracheal tube was used. The amount of propofol used before successful insertion of the airway device was recorded. A pitot-based spirometer was connected and ventilatory variables were measured immediately after insertion. Pulse rate, non-invasive arterial blood pressure, haemoglobin oxygen saturation, respiratory rate, end-tidal carbon dioxide and volatile anaesthetic consumption were also monitored during the surgical procedure; extubation time was noted as well. Results The use of LMA required significantly less propofol (0.8 to 4 mg/kg) for insertion than the ETT (1.2 to 5.6 mg/kg), and the difference was statistically significant (P < 0.01). No differences were observed in ventilatory variables measured immediately after airway positioning. Intraoperatively, there were no differences between groups for respiratory and cardiovascular variables, and amount of isoflurane administered. In all rabbits mean and diastolic blood pressure progressively decreased during surgery. Mean extubation time was shorter in group LMA (6 ± 2 min) than group ETT (8 ± 3 min, P < 0.01). Conclusion The airway device did not clinically affect the cardiovascular and respiratory variables during anaesthesia. Intraoperative hypoventilation was observed in most rabbits regardless of the device being used; therefore ventilatory support may be required. Rabbits with the laryngeal masks were extubated earlier.

Publisher

Springer Science and Business Media LLC

Subject

General Veterinary,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3