Abstract
Abstract
Background
Heterophilic antibodies in serum and plasma can interfere with mammalian antibodies in immunoassays and result in false test results, usually false positive. Although studies screening for heterophilic antibodies as well as elimination studies have been conducted in dogs and cats, knowledge of the presence of heterophilic antibodies in other species in veterinary medicine is limited. In this study, a 2-site sandwich-type interference assay that detects anti-mouse antibodies was used to detect heterophilic antibodies in a population of horses treated in an animal hospital.
Results
A total of 194 serum samples from 127 individual horses were analyzed. There were 11/127 (8.7%) interference-positive horses, and these were analyzed in an assay exchanging the capture mouse IgG with chicken IgY. The positive samples were negative in the chicken IgY assay, indicating elimination of a possible interference, with the chicken-based assay. Four interference-positive samples were from geldings, and anti-Müllerian hormone (AMH) was analyzed from these samples. AMH concentrations were negative in these samples as expected in geldings, indicating that the heterophilic antibodies did not cause interference in the AMH assay.
Conclusion
The present study shows that there are heterophilic antibodies in horse serum samples like in samples from humans, dogs, and cats. The use of chicken-based reagents, such as chicken IgY, which do not cross-react with mammalian IgG, eliminates the effects of interfering antibodies in the samples. Equine heterophilic antibodies do not necessarily cause interference in commercial immunoassays.
Funder
Natural Science Foundation of Fujian Province
Swedish University of Agricultural Sciences
Publisher
Springer Science and Business Media LLC
Subject
General Veterinary,General Medicine
Reference31 articles.
1. Bolstad N, Warren DJ, Nustad K. Heterophilic antibody interference in immunometric assays. Best Pract Res Clin Endocrinol Metab. 2013;27:647–61.
2. Bolstad N, Warren DJ, Bjerner J, Kravdal G, Schwettmann L, Olsen KH, et al. Heterophilic antibody interference in commercial immunoassays; a screening study using paired native and pre-blocked sera. Clin Chem Lab Med. 2011;49:2001–6.
3. Censi S, Cavedon E, Fernando SW, Barollo S, Bertazza L, Zambonin L, et al. Calcitonin measurement and immunoassay interference: a case report and literature review. Clin Chem Lab Med. 2016;54:1861–70.
4. Mongolu S, Armston AE, Mozley E, Nasruddin A. Heterophilic antibody interference affecting multiple hormone assays: is it due to rheumatoid factor? Scand J Clin Lab Investig. 2016;76:240–2.
5. García-González E, Aramendía M, Álvarez-Ballano D, Trincado P, Rello L. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays laboratory strategies to detect interference. Prac Lab Med. 2016;4:1–0.