Safe temperature range for intraoperative and early postoperative continuous hyperthermic intraperitoneal perfusion in a swine model of experimental distal gastrectomy with Billroth II reconstruction

Author:

Li Sheng,Zhang Yong-lei,Sun Jia-yuan,Hua Ya-wei,Wu Pei-hong

Abstract

Abstract Background The current study sought to investigate the safety of intraoperative and early postoperative continuous hyperthermic intraperitoneal perfusion (IEPCHIP) at different temperatures in a swine model of experimental distal gastrectomy with Billroth II reconstruction. Methods Thirty pigs were randomly divided into 5 groups. Two groups were used as the control groups (groups A1 and A2), and 3 groups were used as the perfusion groups (groups B, C and D). Pigs in group A1 received distal gastrectomy with Billroth II reconstruction only. Pigs in groups A2, B, C and D received the same surgery as group A1, followed by IEPCHIP at 37 ± 0.5°C, 42.5 ± 0.5°C, 43.5 ± 0.5°C or 44.5 ± 0.5°C, respectively. The perfusion time was assessed for each pig in group A2 as well as in the perfusion groups, and the perfusions were performed twice for each group. The first perfusion was conducted intraoperatively, and the second perfusion was initiated 1 day after surgery. Data concerning vital signs and hepatic and renal function were collected. Parameters concerning anastomotic healing, the pathology of the anastomotic tissue and abdominal adhesion were compared. Results The vital signs and hepatic and renal functions of the pigs in groups A1, A2, B and C were not significantly affected by this procedure. In contrast, the vital signs and hepatic and renal functions of the pigs in group D were significantly affected. Compared to the pigs in groups A1, A2 or B, the anastomotic bursting pressure, breaking strength and hydroxyproline content in group C and D pigs were significantly lower. No significant differences were observed in these parameters between groups A1, A2 and B. Abdominal adhesion was more severe in group D pigs. Collagen deposition in group A1, A2 and B pigs was dense in the anastomosis, and inflammatory cell infiltration was observed in group D. Conclusions IEPCHIP at 42.5 ± 0.5°C was safe and caused minimal impairments. However, anastomotic healing was affected by perfusion at 43.5 ± 0.5°C and 44.5 ± 0.5°C, and abdominal adhesion was most severe in the group D animals, which were perfused at 44.5 ± 0.5°C.

Publisher

Springer Science and Business Media LLC

Subject

General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3