Abstract
Abstract
Background
When using traditional extensible intramedullary rods to treat congenital pseudarthrosis of the tibia (CPT), there were cases of re-fracture and internal fixation fracture. Therefore, the authors propose a research hypothesis that a thicker distal extensible intramedullary rod can better protect the tibia and reduce the incidence of refracture
Purpose
To investigate the clinical efficacy of new and traditional extensible intramedullary rods in the treatment of CPT in children
Methods
From January 2017 to December 2021, the clinical data of 49 children with CPT who were treated with traditional extensible intramedullary rod combined surgery (group A) and new extensible intramedullary rod combined surgery (group B) in our hospital were collected. Inclusive criteria: ① Crawford type IV CPT children; ② The operation was performed by the same team. Exclusion criteria: patients with multiple tibial angulation. During follow-up, the initial healing, proximal tibial valgus, tibial length, ankle valgus, refracture and intramedullary rod displacement of CPT children in the two groups were evaluated
Results
It was a retrospective investigation. In group A, 26 cases met the inclusion criteria, 24 cases achieved primary healing, with an primary healing rate of 92%, including 1 case of nonunion due to osteomyelitis complications after surgery, and 1 case of delayed healing, with an average healing time of 4.7 ± 0.8 months. 17 cases (68%) had unequal tibia length, with an average difference of 1.6 ± 0.8 cm. Ankle valgus occurred in 10 cases (40%) with an average of 14.4°±4.8°; Proximal tibial valgus occurred in 6 cases (24%) with an average of 7 °± 1.8 °. 20 cases (80%) had tip of the rod migration.10 cases (40%) had re-fracture; The average follow-up time was 2.4 ± 0.4 years. In group B, 22 patients achieved primary healing, and the primary healing rate was 95%, including 1 case with delayed healing. The average healing time was 4.7 ± 1.7months. 14 cases (61%) had unequal tibia length, with an average difference of 1 ± 0.5 cm. Ankle valgus occurred in 4 cases (17%) with an average of 12.3 °±4.9°; The proximal tibia valgus occurred in 9 cases (39%), with an average of 7.7 °±2.5 °. 14 cases (61%) had new type of intramedullary rod displacement. 3 cases (13%) had re-fracture; The average follow-up time was 2.3 ± 0.6years
Conclusion
Compared with the traditional extended intramedullary rod combined operation, the new type of extended intramedullary rod combined operation has a lower incidence of re-fracture after CPT, but it still needs to be verified by large sample and multi-center research
Publisher
Springer Science and Business Media LLC