Author:
Febrer-Sendra Begoña,Crego-Vicente Beatriz,Nindia Arlette,Martínez-Campreciós Joan,Aixut Sandra,Mediavilla Alejandro,Silgado Aroa,Oliveira-Souto Inés,Salvador Fernando,Molina Israel,Muro Antonio,Sulleiro Elena,Fernández-Soto Pedro
Abstract
Abstract
Background
Malaria is a globally distributed infectious disease. According to the World Health Organization, Angola is one of the six countries that account for over half the global malaria burden in terms of both malaria cases and deaths. Diagnosis of malaria still depends on microscopic examination of thin and thick blood smears and rapid diagnostic tests (RDTs), which often lack analytical and clinical sensitivity. Molecular methods could overcome these disadvantages. The aim of this study was to evaluate, for the first time to our knowledge, the performance of a loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria in an endemic area in Cubal, Angola, and to assess the reproducibility at a reference laboratory.
Methods
A total of 200 blood samples from patients attended at Hospital Nossa Senhora da Paz, Cubal, Angola, were analysed for Plasmodium spp. detection by microscopy, RDTs, and LAMP. LAMP assay was easily performed in a portable heating block, and the results were visualized by a simple colour change. Subsequently, the samples were sent to a reference laboratory in Spain to be reanalysed by the same colorimetric LAMP assay and also in real-time LAMP format.
Results
In field tests, a total of 67/200 (33.5%) blood samples were microscopy-positive for Plasmodium spp., 98/200 RDT positive, and 112/200 (56%) LAMP positive. Using microscopy as reference standard, field LAMP detected more microscopy-positive samples than RDTs (66/67; 98% vs. 62/67; 92.5%). When samples were reanalysed at a reference laboratory in Spain using both colorimetric and real-time assays, the overall reproducibility achieved 84.5%.
Conclusions
This is the first study to our knowledge in which LAMP has been clinically evaluated on blood samples in a resource-poor malaria-endemic area. The colorimetric LAMP proved to be more sensitive than microscopy and RDTs for malaria diagnosis in field conditions. Furthermore, LAMP showed an acceptable level of reproducibility in a reference laboratory. The possibility to use LAMP in a real-time format in a portable device reinforces the reliability of the assay for molecular diagnosis of malaria in resource-poor laboratories in endemic areas.
Graphical Abstract
Funder
Junta de Castilla y León
Instituto de Salud Carlos III
Publisher
Springer Science and Business Media LLC
Subject
Infectious Diseases,Parasitology,General Veterinary
Reference43 articles.
1. Tavares W, Morais J, Martins JF, Scalsky RJ, Stabler TC, Medeiros MM, et al. Malaria in Angola: recent progress, challenges and future opportunities using parasite demography studies. Malar J BioMed Central. 2022;21:396.
2. Ashley EA, Pyae Phyo A, Woodrow CJ. Malaria. Lancet. 2018;391:1608–21.
3. World Health Organization (WHO). World malaria report 2022. 2022. https://www.who.int/teams/global-malaria-programme/reports/world-malaria-report. Accessed 1 Mar 2023.
4. Fitri LE, Widaningrum T, Endharti AT, Prabowo MH, Winaris N, Nugraha RYB. Malaria diagnostic update: from conventional to advanced method. J Clin Lab Anal. 2022;36:1–14.
5. Maltha J, Gillet P, Jacobs J. Malaria rapid diagnostic tests in endemic settings. Clin Microbiol Infect Eur Soc Clin Infect Dis. 2013;19:399–407.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献