Performance evaluation of the novel portable PIMA point-of-care CD4 analyzer in comparison with conventional flow cytometer instruments in Cameroon

Author:

Sagnia Bertrand,Kamgaing Rachel,Kouanfack Charles,Kamdem Georgette,Sosso Samuel,Temgoua Edith,Tsomo Zéphyrin,Mabouli Zoa Lucille,Tangimpundu Charlotte,Nchinda Godwin,Ndjolo Alexis

Abstract

Abstract Background Absolute CD4+ T-lymphocyte counts are used in the initiation and monitoring of antiretroviral therapy in HIV-infected patients: with the increase number of HIV infected patient and the reduce number of heath care system in rural zones, HIV monitoring in resource-constrained settings demands affordable and reliable CD4+ T lymphocytes enumeration methods. We evaluated a simple PIMA POC which is a dedicated system for enumeration that uses immunomagnetic and immunofluorescent technologies. The instrument was designed to be a low-cost, yet reliable and robust one. In this study, we assessed the correlation between most representative flow cytometry instruments present in Cameroon instead of CyFlow from PARTEC, FACSCount, and FACSCalibur both from Becton Dickinson. Methods CD4 surface markers on lymphocytes was measured on samples collected in EDTA tubes from 268 patients aged from 1 to 65 years old in three different health care structures. HIV infected patients are coming from CIRCB, Day Hospital of Hopital Central de Yaounde (HCY) and Hopital General de Yaounde (HGY). After inform consent, samples were collected and 101 samples were tested with the FACSCalibur, 60 samples were tested with the CyFlow and 107 samples were tested with the FACSCount flow cytometers. All these samples were tested by different technician with PIMA POC present in all these health care structures and the correlation and agreement were analyzed using linear regression and Bland–Altman analysis. Results The PIMA POC system has excellent precision, accuracy and linearity for CD4+ T lymphocytes enumeration. Good correlations were obtained between the PIMA POC system and other single platform methods. Bland–Altman plots showed interchangeability between the three machines. Absolute CD4+ T-lymphocyte values obtained from the PIMA system correlated well with Cyflow, FACSCount, and FACSCalibur method (r2 varies from 0.88 to 0.968, P < 0.0001). The comparison between values obtained from PIMA with CYFLOW, FACSCount, and FACSCalibur give P = 0.17, P = 0.5 and P = 0.6 respectively meaning that there is not significant differences between values obtained with PIMA and other flow machines. Conclusion This POC PIMA system is a simple and reliable system for enumeration of absolute CD4+ T-lymphocytes. Having one PIMA system easy to use, should reduce the cost and thus increase access to CD4 testing for HIV infected patients in resource-constrained countries. POC CD4 may also alleviate testing burdens at traditional central CD4 laboratories, hence improving test access in both rural and urban environments. This will reduce also the loss of follow up.

Publisher

Springer Science and Business Media LLC

Reference24 articles.

1. UPDATE UGA. COMMUNITIES AT THE CENTRE: DEFENDING RIGHTS BREAKING BARRIERS REACHING PEOPLE WITH HIV SERVICES; 2019.

2. CNLS: Bulletin de Surveillance Epidémiologique Trimestriel. www.cnls.cm 2018, 001–18(01).

3. OMS: Antiretroviral Therapy for HIV Infection in Adults and Adolescents: Recommendations for a Public Health Approach. WHO. 2010. 2010.

4. Phillips AN, Pillay D, Miners AH, Bennett DE, Gilks CF, Lundgren JD. Outcomes from monitoring of patients on antiretroviral therapy in resource-limited settings with viral load, CD4 cell count, or clinical observation alone: a computer simulation model. Lancet. 2008;371(9622):1443–51.

5. Indira P, Kumar PM, Shalini S, Vaman K. Opportunistic infections among people living with HIV (PLHIV) with diabetes mellitus (DM) attending a tertiary Care Hospital in Coastal City of South India. PLoS One. 2015;10(8):e0136280.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3