Reliability of bioreactance and pulse power analysis in measuring cardiac index during cytoreductive abdominal surgery with hyperthermic intraperitoneal chemotherapy (HIPEC)

Author:

Ylikauma Laura Anneli,Tuovila Mari Johanna,Ohtonen Pasi Petteri,Erkinaro Tiina Maria,Vakkala Merja Annika,Takala Heikki Timo,Liisanantti Janne Henrik,Kaakinen Timo Ilari

Abstract

Abstract Purpose Various malignancies with peritoneal carcinomatosis are treated with cytoreductive surgery and hyperthermic intraperitoneal chemotherapy (HIPEC). The hemodynamic instability resulting from fluid balance alterations during the procedure necessitates reliable hemodynamic monitoring. The aim of the study was to compare the accuracy, precision and trending ability of two less invasive hemodynamic monitors, bioreactance-based Starling SV and pulse power device LiDCOrapid with bolus thermodilution technique with pulmonary artery catheter in the setting of cytoreductive surgery with HIPEC. Methods Thirty-one patients scheduled for cytoreductive surgery were recruited. Twenty-three of them proceeded to HIPEC and were included to the study. Altogether 439 and 430 intraoperative bolus thermodilution injections were compared to simultaneous cardiac index readings obtained with Starling SV and LiDCOrapid, respectively. Bland-Altman method, four-quadrant plots and error grids were used to assess the agreement of the devices. Results Comparing Starling SV with bolus thermodilution, the bias was acceptable (0.13 l min− 1 m− 2, 95% CI 0.05 to 0.20), but the limits of agreement were wide (− 1.55 to 1.71 l min− 1 m− 2) and the percentage error was high (60.0%). Comparing LiDCOrapid with bolus thermodilution, the bias was acceptable (− 0.26 l min− 1 m− 2, 95% CI − 0.34 to − 0.18), but the limits of agreement were wide (− 1.99 to 1.39 l min− 1 m− 2) and the percentage error was high (57.1%). Trending ability was inadequate with both devices. Conclusion Starling SV and LiDCOrapid were not interchangeable with bolus thermodilution technique limiting their usefulness in the setting of cytoreductive surgery with HIPEC.

Funder

Oulun Yliopistollinen Sairaala

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3