No radiographic index predicts difficult intubation using the Optiscope™ in cervical spine surgery patients: a retrospective study

Author:

Oh Hyongmin,Kim Hansol,Yoon Hyun-Kyu,Lee Hyung-Chul,Park Hee-PyoungORCID

Abstract

Abstract Background The Optiscope™ can be used for intubation with minimal neck motion. We retrospectively investigated radiographic predictors of difficult intubation using the Optiscope™ by analyzing preoperative radiographic images. Methods One hundred eighty-four patients who were intubated with the Optiscope™ under manual in-line cervical stabilization for cervical spine surgery were enrolled. Radiographic indices were measured on preoperative cervical spine lateral X-ray and magnetic resonance imaging images. Difficult intubation was defined as failure or time consumption more than 90 s on the first attempt. To identify significant predictors of difficult intubation using the Optiscope™ and evaluate their diagnostic value, multivariable logistic regression and receiver operating characteristic analyses were used. Results Fourty-seven patients showed difficult intubation. There was no significant difference in radiographic indices between the difficult and easy intubation groups, but higher body mass index (BMI) (26.5 [3.0] vs. 24.6 [3.5] kg/m2, P = 0.001), shorter sternomental distance (SMD) (122.0 [104.0 to 150.0] vs. 150.0 [130.0 to 170.0] mm, P = 0.001), shorter interincisor gap (40.0 [35.0 to 45.0] vs. 43.0 [40.0 to 50.0] mm, P = 0.006), and higher incidence of excessive oral secretions (10.6% vs. 2.9%, P = 0.049) were observed in patients with difficult intubation. In multivariable analysis, BMI (odds ratio [95% confidence interval]; 1.15 [1.03 to 1.28], P = 0.011) and SMD (odds ratio [95% confidence interval]; 0.98 [0.97 to 1.00], P = 0.008) were associated with difficult intubation with the Optiscope™. In receiver operating characterstic analysis, the area under the curve for body mass index was 0.68 (95% confidence interval; 0.60 to 0.77, P < 0.001) and that for sternomental distance was 0.66 (95% confience interval; 0.57 to 0.75, P = 0.001). Conclusions The incidence of difficult intubation using the Optiscope™ under manual in-line cervical stabilization was 25.5% in cervical spine surgery patients. No significant predictor of difficult intubation with the Optiscope™ was identified among the measured radiographic indices. Although high BMI and short SMD were predictive of difficult intubation with the Optiscope™, their discrimination power was weak.

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3