AutoFlow® versus volume-controlled ventilation for laparoscopic gynecological surgery using LMA® ProSeal™: a randomized controlled trial

Author:

Nakanishi Toshiyuki,Sakamoto Seishi,Yoshimura Manabu,Toriumi Takashi

Abstract

Abstract Background During laparoscopic gynecological surgery, increased peak airway pressure (PAWP) can cause airway leak upon ventilation with the LMA® ProSeal™. We hypothesized that compared with the use of volume-controlled ventilation (VCV), the use of the AutoFlow® mode would decrease PAWP and airway leak during laparoscopic gynecological surgery with LMA ProSeal. Methods This single-center, randomized, controlled trial allocated 80 adult women undergoing elective laparoscopic gynecological surgery to one of two groups, namely, the AutoFlow group or the VCV group. Ventilation settings for both groups were 8 ml/kg of tidal volume and 5 cmH2O of positive end-expiratory pressure, and respiratory rate was adjusted to maintain end-tidal carbon dioxide at 35–40 mmHg. Airway leak, PAWP, and other ventilatory parameters and vital signs were recorded at four timepoints (1, 1 min after insertion of the gastric tube; 2, 2 min after intravenous administration of rocuronium 0.6–0.8 mg/kg; 3, 1 min after initiation of pneumoperitoneum; and 4, 1 min after changing to the Trendelenburg position). The primary outcome was PAWP during pneumoperitoneum and in the Trendelenburg position, whereas the secondary outcomes included PAWP at other timepoints and airway leak development. We used the Mann–Whitney U test for PAWP and Fisher’s exact test for comparing airway leak among the groups. Results Data from 40 patients in the AutoFlow group and 39 in the VCV group were used for analysis. PAWP at pneumoperitoneum pressure and in the Trendelenburg position was significantly lower in the AutoFlow group than in the VCV group [median (interquartile range), 16 (15–18) cmH2O vs. 18 (17–19) cmH2O; P < 0.001]. Similarly, patients in the AutoFlow group showed lower PAWP at the other three timepoints measured. Airway leak occurred in four patients in the AutoFlow group and in two patients in the VCV group; however, this incidence was not significantly different (P = 0.68). Conclusions Even though AutoFlow ventilation decreased PAWP, it did not reduce the incidence of airway leak compared with VCV during laparoscopic gynecological surgery with the LMA ProSeal. Trial registration UMIN Clinical Trials Registry, identifier UMIN000023173.

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3