Variations of pulse pressure and central venous pressure may predict fluid responsiveness in mechanically ventilated patients during lung recruitment manoeuvre: an ancillary study

Author:

Desebbe Olivier,Mondor Whitney,Gergele Laurent,Raphael Darren,Vallier Sylvain

Abstract

Abstract Background Maintaining a constant driving pressure during a prolonged sigh breath lung recruitment manoeuvre (LRM) from 20 to 45 cmH20 peak inspiratory pressure in mechanically ventilated patients has been shown to be a functional test to predict fluid responsiveness (FR) when using a linear regression model of hemodynamic parameters, such as central venous pressure (CVP) and pulse pressure (PP). However, two important limitations have been raised, the use of high ventilation pressures and a regression slope calculation that is difficult to apply at bedside. This ancillary study aimed to reanalyse absolute variations of CVP (ΔCVP) and PP (ΔPP) values at lower stages of the LRM, (40, 35, and 30 cm H20 of peak inspiratory pressure) for their ability to predict fluid responsiveness. Methods Retrospective analysis of a prospective study data set in 18 mechanically ventilated patients, in an intensive care unit. CVP, systemic arterial pressure parameters and stroke volume (SV) were recorded during prolonged LRM followed by a 500 mL crystalloid volume expansion. Patients were considered as fluid responders if SV increased more than 10%. Receiver-operating curves (ROC) analysis with the corresponding grey zone approach were performed. Results Areas under the ROC to predict fluid responsiveness for ΔCVP and ΔPP were not different between the successive stepwise increase of inspiratory pressures [0.88 and 0.89 for ΔCVP at 45 and 30 cm H20 (P = 0.89), respectively, and 0.92 and 0.95 for ΔPP at 45 and 30 cm H20, respectively (P = 0.51)]. Using a maximum of 30 cmH2O inspiratory pressure during the LRM, ΔCVP and ΔPP had a threshold value to predict fluid responsiveness of 2 mmHg and 4 mmHg, with sensitivities of 89% and 89% and specificities of 67% and 89%, respectively. Combining ΔPP and ΔCVP decreased the proportion of the patients in the grey zone from 28 to 11% and showed a sensitivity of 88% and a specificity of 83%. Conclusions A stepwise PEEP elevation recruitment manoeuvre of up to 30 cm H20 may predict fluid responsiveness as well as 45 cm H20. The combination of ΔPP and ΔCVP optimizes the categorization of responder and non-responder patients.

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3