Author:
Lee Seohee,Nam Karam,Park Sang Joon,Ju Jae-Woo,Cho Youn Joung,Jeon Yunseok
Abstract
Abstract
Background
This study evaluated the effect of head rotation on the first-attempt success rate of i-gel insertion, aiming to alleviate the effect of gravity on the tongue and reduce resistance between the device and the tongue.
Methods
Adult surgical patients were randomized to standard and head rotation technique groups. In the head rotation technique group, patients’ heads were maximally rotated to the left before i-gel insertion. The primary endpoint was the first-attempt success rate. Secondary endpoints included the success rate within two attempts (using the allocated technique), time required for successful i-gel placement within two attempts, and success rate at the third attempt (using the opposite technique).
Results
Among 158 patients, the head rotation technique group showed a significantly higher first-attempt success rate (60/80, 75.0%) compared to the standard technique group (45/78, 57.7%; P = 0.021). The success rate within two attempts was similar between the groups (95.0% vs. 91.0%, P = 0.326). The time required for successful i-gel placement was significantly shorter in the head rotation technique (mean [SD], 13.4 [3.7] s vs. 16.3 [7.8] s; P = 0.030). When the head rotation technique failed, the standard technique also failed in all cases (n = 4), whereas the head rotation technique succeeded in five out of the seven patients where the standard technique failed.
Conclusions
The head rotation technique significantly improved the first-attempt success rate and reduced the time required for successful i-gel insertion. It was effective when the standard technique failed. The head rotation technique may be an effective primary or alternative method for i-gel insertion.
Clinical trial registration
ClinicalTrials.gov (NCT05201339).
Publisher
Springer Science and Business Media LLC