Analgesia and spread of erector spinae plane block in breast cancer surgeries: a randomized controlled trial

Author:

Abdella Ahmed Mohamed Mohamed Rabah,Arida Emad Eldin Abd El Monem,Megahed Nagwa Ahmed,El-Amrawy Wessam Zakaria,Mohamed Walid Mohamed Ahmed

Abstract

Abstract Background To evaluate the analgesic efficacy and spread of variable volumes of local anesthetics (LA) in Erector spinae plane block (ESPB). Methods Sixty patients aged between 18 and 50 years with an ASA I-II and scheduled for breast cancer surgery were randomized to receive either ESPB with 20 ml 0.25% bupivacaine (Standard volume ESPB), or with 40 ml 0.125% bupivacaine (High volume ESPB), or no ESPB (GA only group). The primary outcome was pain intensity evaluated by the visual analogue scale (VAS), 12 hours after surgery. P-values < 0.05 were considered the cutoff point for statistical significance. The secondary outcomes were pain at rest and pain on movement evaluated by the VAS, craniocaudal injectate spread, to paravertebral (PV) and epidural spaces assessed by CT, clinical dermatomal spread, level of sedation or agitation, and patient satisfaction with anesthesia and analgesia. Results VAS at rest 12 h after surgery was less in both intervention groups compared to the control (1.75 ± 0.79 vs. 1.6 ± 0.88 vs. 3.4 ± 1.96, p = 0.001). The LA had extended further in the high volume group than the standard volume group (11.20 ± 3.07 vs. 9.15 ± 2.54 vertebral levels, p = 0.027). No difference of the spread to PV or epidural spaces between the 2 intervention groups. More dermatomes were covered in the high volume group (7.20 ± 2.12 vs. 5.75 ± 1.37 dermatomes, p = 0.014). Agitation was higher in the GA only group than both ESPB groups in the first 8 postoperative hours. Patients were more satisfied in both ESPB groups than the GA only group. Conclusions Preoperative ESPB is an excellent analgesic modality and it can also attenuate both postoperative agitation and sedation. Doubling the injectate volume enhances the craniocaudal spreading and may be useful for surgeries requiring multiple dermatomes. However, larger volume has no effect on analgesic efficacy or patient satisfaction as there is no further spread to the PV, epidural spaces or spinal nerve rami. Trial registration NCT04796363 (12/3/2021).

Funder

Alexandria University

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3