Author:
Balafar Moloud,Pouraghaei Mahboub,Paknezhad Seyed Pouya,Abad Saba Nemati Ahmad,Soleimanpour Hassan
Abstract
Abstract
Background
Bag-Mask Ventilation (BMV) is a crucial skill in managing emergency airway situations and induction of general anesthesia. Ensuring proficient BMV execution is imperative for healthcare providers. Various techniques exist for performing BMV. This study aims to compare the quality of ventilation achieved using the E/C technique, Thenar Eminence (T/E) technique and a novel approach referred to as the hook technique. The goal is to identify the most effective single-person BMV method.
Method
We conduct a pilot study on manikins involving 63 medical staff members who used the hook technique for ventilation. Subsequently, we obtained ethical approval and patient guardian consent to perform the study on 492 emergency department (ED) patients. These patients were randomly divided into three groups, with each group subjected to one three ventilation techniques. The study focused on patients requiring reliable airway management for rapid sequence intubation (RSI). Ventilation was administrated using bag-mask device connected to the capnograph. End-tidal CO2 (ETCO2) levels were recorded. Demographic data were collected and analyzed by SPSS software version 22. Success rates were reported as frequency (percentage) as well as mean ± standard deviation.
Result
Comparing partial pressure of CO2 (PCO2) results obtained via capnography between T/E, E/C and hook techniques, we found that the successful ventilation rate was 87.2% for T/E, 89.6% for E/C, and 93.3% for the hook methods. The hook method demonstrated significantly higher success rate compared to the other two techniques (P-value = 0.038). Furthermore, we observed statistically significant trends in PCO2 changes between measurements both within and between groups (P-value < 0/001).
Conclusion
Our study indicates that the hook method achieved notably higher success rate in ventilation compared to the T/E and E/C methods. This suggests that the hook method, which involves a chin lift maneuver while securely fitting the mask, could serve as a novel BMV technique, particularly for resuscitation with small hands for a prolonged use without fatigue and finger discomfort. Our finding contributes to the development of a new BMV method referred to as the hook technique.
Trial registration
IRCT registration number: IRCT20121010011067N5. URL of trial registry record: https://www.irct.ir/trial/57420.
Publisher
Springer Science and Business Media LLC
Subject
Anesthesiology and Pain Medicine
Reference9 articles.
1. Soleimanpour H, Sarahrudi K, Hadju S, Golzari SEJ. How to overcome difficult-bag-Mask-Ventilation: recent approaches. Emerg Med. 2012;2:e116.
2. Weiss AM, Lutes M. Focus on-bag-valve mask ventilation. ACEP News September. 2008 Sep.
3. El-Orbany M, Woehlck HJ. Difficult Mask Ventilation. Anesthesia & analgesia. 2009;109:1870–1880.
4. Morrison LJ, Deakin CD, Morley PT, Callaway CW, Kerber RE, Kronick SL, Lavonas EJ, Link MS, Neumar RW, Otto CW, Parr M, Shuster M, Sunde K, Peberdy MA, Tang W, Hoek TL, Bo ̈ttiger BW, Drajer S, Lim SH, Nolan JP, Advanced Life Support Chapter Collaborators. Adult advanced cardiovascular life support: 2010 American Heart Association guidelines for Cardiopulmonary resuscitation and emergency cardiovascular care. Circulation. 2010;122:S729–67.
5. Umesh G, Krishna R, Chaudhuri S, et al. E-O technique is superior to E-C technique in manikins during single person bag mask ventilation performed by novices. J Clin Monit Comput. 2014;28:269–73.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献