Supine transfer test-induced changes in cardiac index predict fluid responsiveness in patients without intra-abdominal hypertension

Author:

Zhao Zhiyong,Zhang Zhongwei,Liu Jing,Xia Zhili,Xing Qian,Zhang Yaodong,Zheng Yijun,Shen Lihua,Lin Qionghua,Gu Danyan,Wang Pengmei,Zhang Shan,Li Fangfang,Zhu Biao

Abstract

Abstract Background The reversible maneuver that mimics the fluid challenge is a widely used test for evaluating volume responsiveness. However, passive leg raising (PLR) does have certain limitations. The aim of the study is to determine whether the supine transfer test could predict fluid responsiveness in adult patients with acute circulatory failure who do not have intra-abdominal hypertension, by measuring changes in cardiac index (CI). Methods Single-center, prospective clinical study in a 25-bed surgery intensive care unit at the Fudan University Shanghai Cancer Center. Thirty-four patients who presented with acute circulatory failure and were scheduled for fluid therapy. Every patient underwent supine transfer test and fluid challenge with 500 mL saline for 15–30 min. There were four sequential steps in the protocol: (1) baseline-1: a semi-recumbent position with the head of the bed raised to 45°; (2) supine transfer test: patients were transferred from the 45° semi-recumbent position to the strict supine position; (3) baseline-2: return to baseline-1 position; and (4) fluid challenge: administration of 500 mL saline for 15–30 min. Hemodynamic parameters were recorded at each step with arterial pulse contour analysis (ProAQT/Pulsioflex). A fluid responder was defined as an increase in CI ≥ 15% after fluid challenge. The receiver operating characteristic curve and gray zone were defined for CI. Results Seventeen patients were fluid challenge. The r value of the linear correlations was 0.73 between the supine transfer test- and fluid challenge-induced relative CI changes. The relative changes in CI induced by supine transfer in predicting fluid responsiveness had an area under the receiver operating characteristic curve of 0.88 (95% confidence interval 0.72–0.97) and predicted a fluid responder with 76.5% (95% confidence interval 50.1–93.2) sensitivity and 88.2% (95% confidence interval 63.6–98.5) specificity, at a best threshold of 5.5%. Nineteen (55%) patients were in the gray zone (CI ranging from -3 and 8 L/min/m2). Conclusion The supine transfer test can potentially assist in detecting fluid responsiveness in patients with acute circulatory failure without intra-abdominal hypertension. Nevertheless, the small threshold and the 55% gray zone were noteworthy limitation. Trial registration Predicting fluid responsiveness with supine transition test (ChiCTR2200058264). Registered 2022–04-04 and last refreshed on 2023–03-26, https://www.chictr.org.cn/showproj.html?proj=166175.

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3