Effect of individualized PEEP titration guided by intratidal compliance profile analysis on regional ventilation assessed by electrical impedance tomography – a randomized controlled trial

Author:

Weber JonasORCID,Gutjahr Jan,Schmidt Johannes,Lozano-Zahonero Sara,Borgmann Silke,Schumann Stefan,Wirth Steffen

Abstract

Abstract Background The application of positive end-expiratory pressure (PEEP) may reduce dynamic strain during mechanical ventilation. Although numerous approaches for PEEP titration have been proposed, there is no accepted strategy for titrating optimal PEEP. By analyzing intratidal compliance profiles, PEEP may be individually titrated for patients. Methods After obtaining informed consent, 60 consecutive patients undergoing general anesthesia were randomly allocated to mechanical ventilation with PEEP 5 cmH2O (control group) or PEEP individually titrated, guided by an analysis of the intratidal compliance profile (intervention group). The primary endpoint was the frequency of each nonlinear intratidal compliance (CRS) profile of the respiratory system (horizontal, increasing, decreasing, and mixed). The secondary endpoints measured were respiratory mechanics, hemodynamic variables, and regional ventilation, which was assessed via electrical impedance tomography. Results The frequencies of the CRS profiles were comparable between the groups. Besides PEEP [control: 5.0 (0.0), intervention: 5.8 (1.1) cmH2O, p < 0.001], the respiratory and hemodynamic variables were comparable between the two groups. The compliance profile analysis showed no significant differences between the two groups. The loss of ventral and dorsal regional ventilation was higher in the control [ventral: 41.0 (16.3)%; dorsal: 25.9 (13.8)%] than in the intervention group [ventral: 29.3 (17.6)%; dorsal: 16.4 (12.7)%; p (ventral) = 0.039, p (dorsal) = 0.028]. Conclusions Unfavorable compliance profiles indicating tidal derecruitment were found less often than in earlier studies. Individualized PEEP titration resulted in slightly higher PEEP. A slight global increase in aeration associated with this was indicated by regional gain and loss analysis. Differences in dorsal to ventral ventilation distribution were not found. Trial registration This clinical trial was registered at the German Register for Clinical Trials (DRKS00008924) on August 10, 2015.

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3