Abstract
Abstract
Background
The endotracheal cuff pressure depends on the airway pressure during positive-pressure ventilation. A high endotracheal cuff pressure may be related to intraoperative coughing, which can be detrimental during neurosurgery. We investigated the incidence of intraoperative coughing and its association with peak inspiratory pressure (PIP) during neurosurgery under general anesthesia without neuromuscular blockade.
Methods
This retrospective study divided 1656 neurosurgical patients who underwent total intravenous anesthesia without additional neuromuscular blockade after tracheal intubation into high (PIP > 21.6 cmH2O, n = 318) and low (PIP ≤ 21.6 cmH2O, n = 1338) PIP groups. After propensity score matching, 206 patients were selected in each group. Demographic, preoperative, surgical, and anesthetic data were collected retrospectively from electronic medical records and continuous ventilator, infusion pump, and bispectral index data from a data registry.
Results
Intraoperative coughing occurred in 30 (1.8%) patients, including 9 (0.5%) during the main surgical procedure. Intraoperative coughing was more frequent in the high PIP group than in the low PIP group before (14/318 [4.4%] vs. 16/1338 [1.2%], P < 0.001) and after (13/206 [6.3%] vs. 1/206 [0.5%], P = 0.003) propensity score matching. In multivariable logistic regression analysis after propensity score matching, a high PIP (odds ratio [95% confidence interval] 14.22 [1.81-111.73], P = 0.012), tidal volume divided by predicted body weight (mL/kg, 1.36 [1.09–1.69], P = 0.006), and surgical duration (min, 1.01 [1.00–1.01], P = 0.025) predicted intraoperative coughing.
Conclusion
The incidence of intraoperative coughing was 1.8% in neurosurgical patients undergoing general anesthesia without neuromuscular blockade and might be associated with a high PIP.
Publisher
Springer Science and Business Media LLC
Subject
Anesthesiology and Pain Medicine
Reference30 articles.
1. Kawaguchi M, Iida H, Tanaka S, Fukuoka N, Hayashi H, Izumi S, et al. A practical guide for anesthetic management during intraoperative motor evoked potential monitoring. J Anesth. 2020;34:5–28.
2. Akavipat P, Hungsawanich N, Jansin R. Alternative placement of bispectral index electrode for monitoring depth of anesthesia during neurosurgery. Acta Med Okayama. 2014;68:151–5.
3. Macdonald DB, Skinner S, Shils J, Yingling C. American Society of Neurophysiological M: intraoperative motor evoked potential monitoring - a position statement by the American Society of Neurophysiological Monitoring. Clin Neurophysiol. 2013;124:2291–316.
4. Cheng G, Hao S, Ye Z, Wang B, Huangpu B, Zhang P, et al. Potential risk analysis and experience summarization of unstable factors of cranial fixation devices in neurosurgical operations: three-case reports and systematic review. Chin Neurosurg J. 2021;7:25.
5. Lavanchy L, Garvayo M, Abed-Maillard S, Ben-Hamouda N. Caution during endotracheal suctioning in case of skull base fractures! Eur Rev Med Pharmaco. 2021;25:3803–6.