Major pneumothorax during pediatric cardiac MRI procedure under general anesthesia: step-by-step analysis and importance of a well-known environment and material

Author:

Delhez Quentin,Bairy Laurent,Mitchell John,Maseri Adrien

Abstract

Abstract Background To perform step-by-step analysis of the different factors (material, anesthesia technique, human, and location) that led to major pneumothorax during an infrequent pediatric cardiac MRI and to prevent its occurrence in the future. Anesthesia equipment used in a remote location is often different than those in operating rooms. For magnetic resonance imaging (MRI), ventilation devices and monitors must be compatible with the magnetic fields. During cardiac MRI numerous apneas are required and, visual contact with the patient is limited for clinical evaluation. Anesthesia-related barotrauma and pneumothorax are rare in children and the first symptoms can be masked. Case Presentation A 3-year-old boy with atrial septal defect (ASD) and suspicious partial anomalous pulmonary venous return was anesthetized and intubated to perform a follow up with MRI. Sevoflurane maintenance and ventilation were performed using a circular CO2 absorber device, co-axial circuit, and 500 mL pediatric silicone balloon. Apneas were facilitated by Alfentanyl boluses and hyperventilation. A few moderated desaturations occurred during the imaging sequences without hemodynamic changes. At the end of the MRI, facial subcutaneous emphysema was observed by swollen eyelids and crackling snow neck palpation. A complete left pneumothorax was diagnosed by auscultation, sonography examination, and chest radiograph. Pneumo-mediastinum, -pericardium and -peritoneum were present. A chest drain was placed, and the child was extubated and transferred to the pediatric intensive care unit (PICU). Despite the anesthesiologist’s belief that PEEP was minimal, critical analysis revealed that PEEP was maintained at a high level throughout anesthesia. After the initial barotrauma, repeated exposure to high pressure led to the diffusion of air from the pleura to subcutaneous tissues and mediastinal and peritoneal cavities. Equipment check revealed a functional circular circuit; however, the plastic adjustable pressure-limiting valve (APL) closed within the last 30° rotation. The balloon was found to be more rigid and demonstrated significantly reduced compliance. Conclusions Anesthetists require proficiency is using equipment in non-OR locations and this equipment must be properly maintained and checked for malfunctions. Controlling the human factor risks by implementing checklists, formations, and alarms allows us to reduce errors. The number of pediatric anesthesia performed routinely appeared to be essential for limiting risks and reporting our mistakes will be a benefit for all who care about patients.

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3