LMA® protector™ in patients undergoing laparoscopic surgeries: a multicenter prospective observational study

Author:

Liu Yanhong,Song Yuxiang,Wang Miaomiao,Yang Meihua,Shen Hao,Wang Zhen,Chen Liyong,Yang Jianjun,Gong Shengkai,Yu Yonghao,Shi Zhao,Zhang Wei,Zou Xuli,Sun Xude,Wang Yuan,Fu Qiang,Cao Jiangbei,Mi Weidong

Abstract

Abstract Background Laryngeal masks airway (LMA) has been increasingly used in surgical patients. However, the use of LMA in laparoscopic surgeries remains controversial. The major concerns include the potential risk of esophageal regurgitation, aspiration, and difficulties to achieve effective ventilation. The aim of this study was to evaluate the safety and effectiveness of the LMA® Protector™ in patients undergoing laparoscopic surgery. Methods Patients aged 18 to 70 years, scheduled for laparoscopic surgeries were included. The insertion time, successful insertion rate, and oropharyngeal leak pressure were measured. Airway complications and airway manipulations during the procedure were documented. Effective ventilation rate was calculated. Visible bloodstains and reflux content in the drainage channel were documented after the removal of LMA® Protector™. Results Three hundred patients were enrolled. The insertion of LMA® Protector™ failed in seven patients resulting with a successful insertion rate of 97.7%. During the maintenance of anesthesia, airway manipulation was required in 19 patients (19/293, 6.48%), in three of whom the LMA was replaced with endotracheal intubation resulting with an effective ventilation rate of 96.7% (290/300). The oropharyngeal leak pressure was 30.18 ± 5.88 cmH2O. Seventy-five patients (25.86%) reported mild sore throat on the first day after surgery. Bloodstains on study devices were noticed in 58 patients (20%). Seventy-five patients (25.86%) reported mild sore throat on the first day after surgery. Gastric reflux was noticed in the drainage tube in 5 patients (1.72%) with no signs of aspiration in any of those patients. Conclusions The LMA® Protector™ was shown to be safe and effective in patients undergoing laparoscopic surgeries. Although minor complications that require no further treatment, no clinically diagnosed aspiration was noticed in our study. Gastric reflux was noticed in the drainage tube in five patients undergoing laparoscopic gynecology surgery. Further research is needed to verify whether LMA® Protector™ is suitable for procedures in Trendelenburg position or other situations that a high risk of gastroesophageal reflux exists. Trial registration The trial was registered at the Chinese Clinical Trial Registry (ChiCTR1800018300, date of registration: September 2018).

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3