Author:
Tercier Stéphane,Gapany Christophe,Diezi Manuel,Clément Chantal,Lemay Katy,Joseph Jean-Marc
Abstract
Abstract
Background
Totally implanted vascular access devices are frequently used in children for repeated blood samples or intravenous treatments. This prospective study aims at identifying the risk factors associated with infections, obstructions and surgical complications of these devices in pediatric patients.
Methods
From January 2006 to January 2008, all children older than one year of age with a diagnosis of solid or blood cell malignancy were included in the study. Insertion was performed by the surgeon according to a standardized protocol after landmark-guided puncture of the subclavian or internal jugular vein by a senior anesthesiologist. Dressing and post-operative care were standardized. Every manipulation was prospectively recorded by specialized dedicated nurses, and all patients were screened for complications one month post-surgery.
Results
45 consecutive patients 1 to 16 years old were enrolled in the study. Mean age at the time of procedure was 8.5 years (range 1.3–15.6; SD ± 4.88). There were 12 peroperative adverse events in 45 procedures (27%), detailed as follows: 3 pneumothoraces (7%), 3 hematomas (7%), 6 arterial punctures (13%). Among these events, intervention was necessary for two pneumothorax and one arterial puncture. There was no air embolism. At one month, we recorded 5 post-operative complications (11%): 2 thrombotic obstructions, one unsightly scar, and one scapular pain of unknown etiology. One patient needed repositioning of the catheter. There was no catheter-related infection.
Conclusion
Prospective recording of TIVA insertion in children reveals a significant number of early incidents and complications, mainly associated with the percutaneous puncture technique. We found no infection in this series. Results of a longer follow-up in the same population are pending.
Publisher
Springer Science and Business Media LLC
Subject
Anesthesiology and Pain Medicine,Orthopedics and Sports Medicine,Surgery
Reference20 articles.
1. Munro FD, Gillett PM, Wratten JC, Shaw MP, Thomas A, MacKinlay Ga, Wallace WH: Totally implantable central venous access devices for paediatric oncology patients. Med Pediatr Oncol. 1999, 33 (4): 377-81. 10.1002/(SICI)1096-911X(199910)33:4<377::AID-MPO6>3.0.CO;2-X.
2. Bow EJ, Kilpatrick MG, Clinch JJ: Totally implantable venous access ports systems for patients receiving chemotherapy for solid tissue malignancies: A randomized controlled clinical trial examining the safety, efficacy, costs, and impact on quality of life. J Clin Oncol. 1999, 17 (4): 1267-
3. Chang L, Tsai JS, Huang SJ, Shih CC: Evaluation of infectious complications of the implantable venous access system in a general oncologic population. Am J Infect Control. 2003, 31 (1): 34-39. 10.1067/mic.2003.29.
4. Koolen DA, van Laarhoven HW, Wobbes T, Punt CJ: Single-centre experience with tunnelled central venous catheters in 150 cancer patients. Netherland Journal of Medicine. 2002, 60 (10): 397-401.
5. Labourey JL, Lacroix P, Genet D, Gobeaux F, Martin J, Venat-Bouvet L, Lavau-Denes S, Maubon A, Tubiana-Mathieu N: Thrombotic complications of implanted central venous access devices: prospective evaluation. Bull Cancer. 2004, 91 (5): 431-6.
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献