Performance of the BD FACSPresto near to patient analyzer in comparison with representative conventional CD4 instruments in Cameroon

Author:

Sagnia Bertrand,Mbakop Ghomsi Fabrice,Gutierrez Ana,Sosso Samuel,Kamgaing Rachel,Nanfack Aubin Joseph,Nji Nadesh,Ambada Georgia,Lissom Abel,Tchouangueu Thibaut Flaurant,Ngu Ndengkoh Loveline,Domkam Irenée,Nchinda Godwin,Ndjolo Alexis

Abstract

Abstract Background In the context of scaling the viral load in resource limited settings, following HIV infected patient’s adults and children with CD4+ T-lymphocyte count still very important in settings where the decentralization of treatment still has some challenges. Effective HIV monitoring in these resource-constrained settings needs affordable and reliable CD4+ T lymphocytes enumeration methods. We investigated the validity of a BD FACSPresto POC which is a dedicated system for enumeration that uses immunofluorescent technologies. In this study, we have assessed the sensitivity, specificity and correlation between most representative flow cytometry instruments present in Cameroon with more than 5000 CD4 T cells tests per year including FACSCalibur, FACSCount, and PIMA POC from Becton–Dickinson and ALERE respectively. Methods 268 patients aged from 1 to 72 years old were enrolled and included in the study after inform consent. The BD FACSPresto POC CD4+ T cell technology was placed at CIRCB and operated by technician staff. HIV infected patients were from Chantal BIYA international reference Center (CIRCB), Centre de Sante Catholique de NKOLODOM, Centre de Sante Catholique de BIKOP and CASS de Nkolndongo—Yaounde We compared the accuracy of the BD FACSPresto and three existing reference technologies with more than 5000 tests per year like FACSCalibur, FACSCount and PIMA according to the number of CD4 test done per year and their repartition in the country. Bland–Altman method and correlation analysis were used to estimate mean bias and 95% limits of agreement and to compare the methods, including analysis by subgroup of participant gestational age. In addition sensitivity and specificity were determined. Statistical significance was set at P-value < 0.05. Results The BD FACSPresto POC system has excellent precision, accuracy and linearity for CD4+ T lymphocytes enumeration. Good correlations were obtained between the BD FACSPresto poc system and other single platform methods. Bland–Altman plots showed interchangeability between two machines mean bias BD-FACSPresto vs PIMA = − 126,522(− 161,221 to − 91,822) BD-FACSPresto vs FACSCount = − 38,708 (− 58,935 to − 18,482) and FACSPresto vs FACSCALIBUR = 0.791(− 11,908 to 13,491). Mean difference with Absolute CD4+ T-lymphocyte values obtained from the BD FACSPresto system correlated well with PIMA, FACSCount, and FACSCalibur method with R2 equal to 0.88, 0.92 and 0.968 respectively with P < 0.001 for all. The mean comparison between values obtained from BD FACSPresto with PIMA, FACSCount, and FACSCalibur using paired T test give P = 0.17, P = 0.5 and P = 0.6 respectively meaning that there is no significant differences between values obtained with BD FACSPresto and PIMA, FACSCount or FACSCalibur CD4 enumeration machines. Further analysis revealed close agreement between all the three instruments with no significant difference between the forth methods (P = 0.91). Conclusion This BD-FACSPresto POC system is a simple, robust and reliable system for enumeration of absolute and percentage of CD4+ T-lymphocytes especially suitable for remote areas with limited resources. Having one BD-FACSPresto POC system easy to use, should reduce the cost and thus increase and improved access to CD4 testing for HIV infected patients in resource-constrained countries. BD-FACSPresto POC CD4 will enable reduction in patient time and improve the overall quality of ART service count and may improve test access in remote areas. This technology can allow for greater decentralization and wider access to CD4 testing and ART.

Publisher

Springer Science and Business Media LLC

Subject

Pharmacology (medical),Virology,Molecular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3