Analytical effect of stabilizer volume and shape on zircon U–Pb dating by nanosecond LA-ICP-QMS

Author:

Xiong Dongyang,Guo Longfei,Liu Chenxi,Wang Long,Liu Yanrong,Tan XijuanORCID

Abstract

AbstractIn this paper, we evaluated the effect of seven stabilizers with different shapes (including cylinder, cubic and ball shape) on zircon U–Pb dating analysis by laser ablation inductively coupled plasma quadrupole mass spectrometry (LA-ICP-QMS) in detail. In the case of stabilizer volume examined, the analytical efficiency of cylinder stabilizers (21.2, 25.1, 35.3 and 125 mL) were investigated in terms of signal stabilization, signal rising/washout time and U–Pb dating accuracy. By using zircon 91500 as reference material for external calibration, the 206Pb/238U age of zircon Plešovice was determined by a nanosecond LA-ICP-QMS, where the stabilizer was placed directly after the ablation cell and sample aerosols carried by helium passed through the stabilizer and subsequently mixed with make-up gas (argon) before ICP. It was found that transient signal oscillations were invisible and signal intensities were comparable using all the stabilizers, while signal rising time was 2.0-fold and washout time was 27.6-fold for stabilizer with volume of 125 mL to that of 21.2 mL. The obtained average 206Pb/238U age of zircon Plešovice was 335.53 ± 1.02, 361.73 ± 5.04, 340.10 ± 1.98 and 341.21 ± 5.17 Ma (2σ, n ≥ 5), respectively, giving average relative deviations of a single point of age (1σ) less than 2.0%. Among the corresponding 206Pb/238U ratios, it was also found that the value (0.05343 ± 0.87‰, 1σ, n = 5) obtained using 21.2 mL of cylinder stabilizer highly agreed with that of 0.05384 ± 0.74‰ (1σ, n = 5) using the commercially available “squid” stabilizer. The analytical efficiency of the 21.2 mL of cylinder stabilizer was then compared to that of cubic shape stabilizer (18.5 mL) and ball shape stabilizer (14.1 mL). Results showed that there were no significant differences of the obtained 206Pb/238U ages using stabilizers with volume in the range of 14.1–21.2 mL. But both cubic and ball shape stabilizers exhibited washout time over 270 s. We also studied the particle filter effect of the stabilizers by packing the 21.2 mL of cylinder stabilizer with 1.0 g of stainless wire. Despite the average 206Pb/238U age deviation was only − 0.81%, spiky signals occasionally occurred which might be ascribed to the use of a nanosecond laser and relatively low density of stainless wire in the stabilizer. This study confirmed that an empty stabilizer with volume of 21.2 mL and cylinder shape was preferred to produce smoothing signals. The improved analytical accuracy of zircon U–Pb dating using such a stabilizer ensured the future application to trace element analysis by LA-ICP-QMS.

Funder

the Natural Science Foundation, China

the National Key Research and Development Project, China

National Resource Center for the First-Year Experience and Students in Transition, University of South Carolina

Publisher

Springer Science and Business Media LLC

Subject

General Physics and Astronomy,General Environmental Science,General Biochemistry, Genetics and Molecular Biology,General Materials Science,General Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3