Evaluation of the quality of fixed prosthesis impressions in private laboratories in a sample from Yemen

Author:

Al-Odinee Nusaiba M.,Al-Hamzi Mohsen,Al-shami Ibrahim Z.,Madfa Ahmed,Al-Kholani Abdulwahab I.,Al-Olofi Yazeed M.

Abstract

Abstract Background Fixed prosthodontics require an accurate impression for the teeth and the area to be restored for the laboratory to fabricate the desired restoration without mistakes. This study evaluated the quality of impressions received by private laboratories for the fabrication of fixed prosthesis by describing the frequency of clinically detectable errors and by analyzing association between the various factors involved. Methods 165 impressions were collected from four dental laboratories. Jaw involved, type of tray, size of tray, number of prepared units, type of impression materials, techniques and viscosity in case of elastomeric impressions and type of prosthesis requested were recorded. Data referring to errors and visible defects including errors in finish line, in preparation area, in silicone impression technique and blood in impression were also documented. Factors affecting errors present were also assessed. Association between dentist gender and experience years and impression errors was assessed. Chi square and Fisher exact tests used to examine the association between categorical variables and outcomes. Results The total of error considering not immediately pouring as an error. Alginate was the most impression used. of impressions evaluated (50.9%), 97% were have at least one visible error; 92.1% had errors in finish line, 53.9% had errors in preparation area and (72.8%) of elastomeric impressions were have at least one error in technique. Blood in impression was detected in 52.1% of impressions. Significant association was found between material type and errors in finishing line and preparation area. Significant relationships were found between gender and errors in silicone impression technique (p < 0.05). Conclusion Within the limitations of this study, high frequency of detectable errors was found in fixed prosthesis impressions received by private dental laboratories. This high frequency is of serious concern, as this will result in poor fitted fixed prosthesis provided to patients.

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3