Impact of different CAD/CAM materials on internal and marginal adaptations and fracture resistance of endocrown restorations with: 3D finite element analysis

Author:

El-Farag Shaimaa Ahmed Abo,Elerian Fatma Abdallah,Elsherbiny Abdallah Ahmed,Abbas Mahy Hassouna

Abstract

Abstract Purpose To assess and compare the impact of various computers aided design/manufacturing (CAD/CAM) materials on internal and marginal discrepancies, fracture resistance and failure probability of Endocrown restorations with 3D Finite Element analysis. Material and methods Forty devitalized human maxillary first molars were collected. After endodontic treatment, they classified into 4 groups (n = 10) based on the materials used for endocrown fabrication. Group V (Vita-Enamic), Group N (Nacera Hybrid), Group T (Translucent Prettau Zirconia) and Group P (Pekkton ivory). All samples were exposed to artificial aging method simulating one year of clinical service. Silicone replica technique and stereomicroscope (25X) utilized to evaluate the marginal and internal gaps of endocrowns at different areas. Fracture resistance test used for cemented specimens followed by qualitative investigation utilizing Stereomicroscopy. Four models representing four endocrown systems used for restoration of severely-damaged endodontically treated upper first molar were generated for finite element analysis (FEA). Axially and centrally static occlusal compressive load was applied. Modified Von Mises and maximum principal stress values on the remaining tooth structure, cement lines and restorative materials were assessed independently. Resulted data were statistically analyzed at P-value ≤ 0.05. Results In the current study, the highest mean values of internal and marginal discrepancies (μm) among studied groups were reported for Zirconia group (100.300 and 102.650) respectively, while the lowest mean value of internal discrepancy (μm) was observed for Nacera group (69.275) and the lowest mean value of marginal discrepancy (μm) was observed for PEKK group (78.4750). Regarding internal discrepancy, Vita-Enamic and PEKK groups did not exhibit any statistically significant differences (P = 0.293), however zirconia and the other tested groups exhibited statistically significant differences in the mean values of the marginal gap region (p 0.05).On the other hand, PEKK group showed the highest mean value of fracture resistance (1845.20 N) and the lowest value was observed for Vita-Enamic group (946.50 N). Regarding to stress distributions through 3D FEA, and according to modified von Mises (mvM) analysis, the greatest possible stress values were noticed in PEKK model in relation to tooth structure, cement line, and flowable composite as the following: (93.1, 64.5, 58.4 MPa) respectively, while Zirconia revealed lower maximum stress values (11.4, 13.6, 11.6 MPa) respectively. Conclusions Statistically excellent marginal and internal fit was observed for PEKK in relation to other used endocrown materials. Also, PEKK material explained fracture resistance comparable to zirconia value while the lowest value was detected for Vita Enamic material.

Funder

Mansoura University

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3