Abstract
Abstract
Background
Accurate assessment of remaining dentin thickness (RDT) is paramount for restorative decisions and treatment planning of vital teeth to avoid any pulpal injury. This diagnostic accuracy study compared the validity and patient satisfaction of an electrical impedance based device Prepometer™ (Hager & Werken, Duisburg, Germany) versus intraoral digital radiography for the estimation of remaining dentin thickness in carious posterior permanent teeth.
Methods
Seventy patients aged 12–25 years with carious occlusal or proximal permanent vital posterior teeth were recruited. Tooth preparation was performed to receive an adhesive restoration. Pre- and post-excavation RDT were measured radiographically by two calibrated raters using the paralleling periapical technique. Prepometer™ measurements were performed by the operator. Patients rated their satisfaction level with each tool on a 4-point Likert scale and 100 mm visual analog scale (VAS). Inter and intragroup comparisons were analyzed using signed rank test, while agreement between devices and observations was tested using weight kappa (WK) coefficient.
Results
the intergroup comparisons showed that, before and after excavation, there was a significant difference between measurements made by both techniques (p < 0.001). After excavation, there was a weak agreement between measurements (WK = 0.2, p < 0.001), whereas before excavation, the agreement was not statistically significant (p = 0.407). Patients were significantly more satisfied with Prepometer™ based on scales and VAS (p < 0.001).
Conclusion
Prepometer™ could be a viable clinical tool for determining RDT with high patient satisfaction, while radiographs tended to overestimate RDT in relation to the Prepometer™.
Publisher
Springer Science and Business Media LLC
Reference31 articles.
1. Fujita R, Komada W, Nozaki K, Miura H. Measurement of the remaining dentin thickness using optical coherence tomography for crown preparation. Dent Mater J. 2014;33(3):355–62. https://doi.org/10.4012/dmj.2013-303.
2. Jiang L, Lin XJ, Chen YH, Yu H. Effects of remaining dentin thickness on the bond strength of bleached dentin. BMC Oral Health. 2020;20(1):1–7.
3. Burns RC, Cohen S. Pulp responses. In: Stanley HR, editor. Pathways of the pulp. 3rd ed. St. Louis: Mosby; 1984. p. 465–89.
4. Berbari R, Khairallah A, Kazan HF, Ezzedine M, Bandon D. Measurement reliability of the remaining dentin thickness below deep carious lesions in primary molars. Int J Clin Pediatr Dent. 2018;11(1):23–8. https://doi.org/10.5005/jp-jour.
5. Purton DG, Chandler NP, Monteith BD, Qualtrough AJ. A novel instrument to determine pulp proximity. Eur J Prosthodont Restor Dent. 2009;17(1):30–4.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Feature Factors that Influence Human Health in Smartwatches;2024 IEEE Symposium on Industrial Electronics & Applications (ISIEA);2024-07-06