Guided endodontics: accuracy of access cavity preparation and discrimination of angular and linear deviation on canal accessing ability—an ex vivo study

Author:

Su Yinghui,Chen Chenghui,Lin Chiahua,Lee Huina,Chen Kerkong,Lin Yenkun,Chuang Fuhsiung

Abstract

Abstract Background Guided endodontics technique has been introduced for years, but the accuracy in different types of teeth has yet to be assessed. The aim of this study is to evaluate the accuracy of three dimensional (3D)-printed endodontic guides for access cavity preparation in different types of teeth, and to evaluate the predictive ability of angular and linear deviation on canal accessibility ex vivo. Method Eighty-four extracted human teeth were mounted into six jaw models and categorised into three groups: anterior teeth (AT), premolar (P), and molar (M). Preoperative cone beam computed tomography (CBCT) and surface scans were taken and matched using implant planning software. Virtual access cavity planning was performed, and templates were produced using a 3D printer. After access cavities were performed, the canal accessibility was recorded. Postoperative CBCT scans were superimposed in software. Coronal and apical linear deviations and angular deviations were measured and evaluated with nonparametric statistics. The receiver operating characteristic (ROC) curve was used to evaluate the predictive ability of angular and linear deviation for canal accessibility in SPSS v20. Results A total of 117 guided access cavities were created and 23 of them were record as canal inaccessibility, but all canals were accessible after canal negotiation. The average linear deviation for all groups was 0.13 ± 0.21 mm at coronal position, 0.46 ± 0.4 mm at apical position, and 2.8 ± 2.6° in angular deviation. At the coronal position, the linear deviations of the AT and P groups were significantly lower than M group deviation (P < 0.05), but no statistically significant difference between AT group and P group. The same results were found in linear deviation at the apical position and in angular deviation. The area under the ROC curve was 0.975 in angular deviation, 0.562 in linear deviation at the coronal position, and 0.786 at the apical position. Statistical significance was noted in linear deviation at the apical position and in angular deviation (P < 0.001). Conclusions In conclusion, this study demonstrated that the accuracy of access cavity preparation with 3D-printed endodontic guides was acceptable. The linear and angular deviations in the M group were significantly higher than those in the other groups, which might be caused by the interference of the opposite teeth. Angular deviation best discriminated the canal access ability of guided access cavity preparation. Graphical Abstract

Funder

Kaohsiung Medical University Hospital

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3