Author:
Keilig L.,Goedecke J.,Bourauel C.,Daratsianos N.,Dirk C.,Jäger A.,Konermann A.
Abstract
Abstract
Background
Increased tooth mobility persists after fixed orthodontic appliance removal, which is therapeutically utilized for post-treatment finishing with positioners. As such a fine adjustment is only required for selected teeth, the aim of this pilot study was to investigate tooth mobility in vivo on corrected and uncorrected subgroups under positioner therapy.
Methods
Mobility was measured on upper teeth of 10 patients (mean age 16.8) by applying loadings for 0.1, 1.0 and 10.0 s with a novel device directly after multibracket appliance debonding as much as 2d, 1, 2 and 6 weeks later. Positioners were inserted at day 2. Specimens were divided into Group C (teeth corrected via positioner), Group N (uncorrected teeth adjacent to teeth from group C), and Group U (uncorrected teeth in an anchorage block). Untreated individuals served as controls (n = 10, mean age 22.4). Statistics were performed via Kolmogorov-Smirnov test and Welch’s unequal variances t-test for comparisons between groups. P < 0.05 was considered statistically significant.
Results
After 1 week, tooth mobility in Group U almost resembled controls (13.0–15.7 N), and reached physiological values after 6 weeks (17.4 N vs. 17.3 N in controls). Group C (9.0–13.4 N) and Group N (9.2–14.7 N) maintained increased mobility after 6 weeks. Tooth mobility was generally higher by reason of long loading durations (10.0 s).
Conclusions
Positioner therapy can selectively utilized increased tooth mobility upon orthodontic fixed appliance treatment for case refinements. Here, uncorrected teeth in anchorage blocks are not entailed by unwanted side effects and recover after 6 weeks post treatment. Corrected teeth and their neighbors exhibit enhanced mobility even after 6 weeks, which represents a necessity for the proper correction of tooth position, and concurrently arouses the requirement for an adequate retention protocol.
Funder
Deutsche Forschungsgemeinschaft
Publisher
Springer Science and Business Media LLC
Reference19 articles.
1. Tanaka E, Ueki K, Kikuzaki M, Yamada E, Takeuchi M, Dalla-Bona D, et al. Longitudinal measurements of tooth mobility during orthodontic treatment using a periotest. Angle Orthod. 2005;75:101–5.
2. Tanne K, Inoue Y, Sakuda M. Biomechanical behavior of the periodontium before and after orthodontic tooth movement. Angle Orthod. 1995;65:123–8.
3. Konermann A, Al-Malat R, Skupin J, Keilig L, Dirk C, Karanis R, et al. In vivo determination of tooth mobility after fixed orthodontic appliance therapy with a novel intraoral measurement device. Clin Oral Investig. 2017;21:1283–9.
4. Lew KK. The orthodontic tooth positioner--an appraisal. Br J Orthod. 1989;16:113–6.
5. Pravindevaprasad A, Therese BA. Tooth positioners and their effects on treatment outcome. J Nat Sci Biol Med. 2013;4:298–301.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献