Abstract
Abstract
Background
Miniscrews have been used to superimpose three-dimensional (3D) craniofacial images as well as explore stable structures in jaws. Our purpose was to evaluate the reliability and validity of linear and angular measurements made with miniscrews on a 3D cone-beam computed tomography (CBCT) at two voxel sizes and compared to models created by an intraoral scanner (IOS).
Methods
Altogether, 64 miniscrews were placed in 12 goat jaws. The jaws were scanned by CBCT machine at 0.12 mm and 0.3 mm voxels and by the IOS. Linear and angular measurements between miniscrews on CBCT at the two voxel settings and the IOS were compared with actual measurements and with each other.
Results
An intra-and inter-class correlation of 0.961–1.000 were obtained by each method. Linear measurements showed significant overestimations of 0.27 ± 0.24, 0.14 ± 0.22 and 0.15 ± 0.26 mm, and angular measurements showed non-significant differences of 0.11 ± 1.97°, 0.15 ± 2.79° and 0.41 ± 2.34° for the CBCT at 0.12-mm, 0.3-mm voxels and the IOS, respectively. Equal magnification of linear measurements was on homolateral and contralateral sides using CBCT, whereas significantly greater magnification on the homolateral side than on the opposite was observed using the IOS. There was no significant difference with angular measurements between digital CBCT models at two voxels and IOS. In addition, all angular measurements were comparable to actual measurement results.
Conclusions
Miniscrews in CBCT and IOS are reliable and clinical valid when used as a reference measuring tooth movement. However, when miniscrews are involved in high precision measurement in CBCT or IOS image, systematic error should be taken into consideration. When comparing CBCT images, using the same voxel size is recommended for miniscrew related measurements to reduce error.
Publisher
Springer Science and Business Media LLC
Reference31 articles.
1. Melsen B. The cranial base: The postnatal development of the cranial base studied histologically on human autopsy material: Birte MelsenActa Odontol. Scand.32:Supp. 62, 1974. Am J Orthod. 1974;66(6):689–91.
2. Bjork A, Skieller V. Normal and abnormal growth of the mandible: a synthesis of longitudinal cephalometric implant studies over a period of 25 years. Eur J Orthod. 1983;5:1–46.
3. Bjork A, Skieller V. Growth of the maxilla in three dimensions as revealed radiographically by the implant method. Br J Orthod. 1977;4:53–64.
4. Enlow DH, Harris DB. A study of the postnatal growth of the human mandible. Amer J Orthod. 1964;50:25–50.
5. Cevidanes LH, Bailey LJ, Tucker GR Jr, Styner MA, Mol A, Phillips CL, Proffit WR, et al. Superimposition of 3D cone-beam CT models of orthognathic surgery patients. Dentomaxillofac Radiol. 2005;34:369–75.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献