Ex vivo detection of mandibular incisors’ root canal morphology using cone-beam computed tomography with 4 different voxel sizes and micro-computed tomography

Author:

Bai Bingbing,Tang Ying,Wu Yihan,Pei Fan,Zhu Qi,Zhu Peng,Gu Yongchun

Abstract

Abstract Background In recent years, cone-beam computed tomography (CBCT) has been widely used to evaluate patients’ root canal anatomy due to its high resolution and noninvasive nature. As voxel size is one of the most important parameters affecting CBCT image quality, the current study evaluated the diagnostic potential of CBCT with 4 different voxel sizes in the detection of double root canal systems and accessory canals (ACs) in permanent mandibular incisors. Methods A total of 106 extracted mandibular permanent incisors were collected from the dental clinics, and then were scanned by using micro-CT with a voxel size of 9 μm. The teeth were then fixed in the tooth sockets of human dry mandibles and scanned by using a CBCT device with 4 different voxel sizes (300, 200, 250, and 125 μm). Four observers detected in blind the root canal morphology of the teeth according to the CBCT images, and the presence or absence of a double root canal system, and the presence or absence of ACs, were scored according to a 5-point scale, respectively. Receiver operating characteristic (ROC) analysis was performed, and DeLong test was used to compare the area under the curve (AUC) values and the micro-CT data was taken as a gold standard. Results Among 106 sample teeth, 25 specimens with a double root canal system were identified by the micro-CT. ROC curve analysis of the data obtained by the four observers showed that in the detection of double root canal systems, the AUC values ranged from 0.765 to 0.889 for 300 μm voxel size, from 0.877 to 0.926 for 250 μm voxel size, from 0.893 to 0.967 for 200 μm voxel size, and from 0.914 to 0.967 for 125 μm voxel size (all p < 0.01). In general, we observed a trend that the AUC values, sensitivity, and specialty increased with the decrease in the voxel size, and significantly higher AUC values were detected in 125 μm voxel size images. In the detection of ACs, ROC curve analysis showed that among the four observers, the AUC values ranged from 0.554 to 0.639 for 300 μm voxel size, from 0.532 to 0.654 for 250 μm voxel size, from 0.567 to 0.626 for 200 μm voxel size, and from 0.638 to 0.678 for 125 μm voxel size. CBCT images at a voxel size of 125 μm had a weak diagnostic potential (AUC: 0.5–0.7, all p < 0.05) in the detection of AC, with a lower sensitivity ranging from 36.8 to 57.9% and a higher specialty ranging from 73.6 to 98.8%. Conclusions CBCT with 300 μm voxel size could only provide moderate diagnostic accuracy in the detection of a double canal system in mandibular incisors. CBCT with a voxel size of 125 μm exhibited high diagnostic value in the detection of double canal systems, while showing low but statistically significant value in the detection of ACs.

Funder

Suzhou “Medical Health Science and Technology Innovation” Project

Suzhou "Promoting Science and Education" Youth Science and Technology Project

Scientific Project of Ninth People’s Hospital

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3