Abstract
Abstract
Background
To investigate the efficacy of a nickel-titanium (NiTi) file with an automated computerized numerical control (CNC) system for root canal shaping.
Methods
The movement of the automated device and the insertion angle were investigated. In Experiment 1, simulated resin root canals were randomly divided into four groups (n = 20): manual downward movement using a handpiece (Group 1), vertical downward movement by CNC (Group 2), reciprocating up and down movement by CNC (Group 3), and spiral up and down movement by CNC (Group 4). In Experiment 2, five different insertion angles of the NiTi file were evaluated (n = 20). Four parameters were used to evaluate the shaping ability: change in the working length, central axis offset, curvature variation, and preparation time. Groups were compared using one-way analysis of variance (ANOVA) with significance was set at P < 0.05.
Results
The change in central axis position in the curved part of the root canal was found to be smaller in Group 4 than in other groups (P < 0.05). The curvature changes and preparation time of Groups 1 and 4 were significantly reduced compared with Groups 2 and 3 (P < 0.05). The variation in working length and curvature in the 5° insertion angle group was significantly smaller than in the other groups (P < 0.05).
Conclusions
A spiral up and down movement, controlled by the CNC machine, and 5° insertion angle, maintained original root canal shape more precisely than other methods.
Funder
Key Technology Research and Development Program of Shandong
Fundamental Research Funds of Shandong University
National Social Science Fund of China
Publisher
Springer Science and Business Media LLC