Individual mandibular movement registration and reproduction using an optoeletronic jaw movement analyzer and a dedicated robot: a dental technique

Author:

Carossa Massimo,Cavagnetto DavideORCID,Ceruti Paola,Mussano Federico,Carossa Stefano

Abstract

Abstract Background Fully adjustable articulators and pantographs record and reproduce individual mandibular movements. Although these instruments are accurate, they are operator-dependant and time-consuming. Pantographic recording is affected by inter and intra operator variability in the individuation of clinical reference points and afterwards in reading pantographic recording themselves. Finally only border movements can be reproduced. Methods Bionic Jaw Motion system is based on two components: a jaw movement analyzer and a robotic device that accurately reproduces recorded movements. The jaw movement analyzer uses an optoelectronic motion system technology made of a high frequency filming camera that acquires 140frames per second and a custom designed software that recognizes and determines the relative distance at each point in time of markers with known geometries connected to each jaw. Circumferential modified retainers connect markers and do not cover any occlusal surfaces neither obstruct occlusion. The recording process takes 5 to 10 s. Mandibular movement performance requires six degrees of freedom of movement, 3 rotations and 3 translations. Other robots are based on the so-called delta mechanics that use several parallel effectors to perform desired movements in order to decompose a complex trajectory into multiple more simple linear movements. However, each parallel effector introduces mechanical inter-component tolerances and mathematical transformations that are required to transform a recorded movement into the combination of movements to be performed by each effector. Bionic Jaw Motion Robot works differently, owing to three motors that perform translational movements and three other motors that perform rotations as a gyroscope. This configuration requires less mechanical components thus reducing mechanical tolerances and production costs. Both the jaw movement analyzer and the robot quantify the movement of the mandible as a rigid body with six degrees of freedom. This represents an additional advantage as no mathematical transformation is needed for the robot to reproduce recorded movements. Results Based on the described procedure, Bionic Jaw Motion provide accurate recording and reproduction of maxillomandibular relation in static and dynamic conditions. Conclusion This robotic system represents an important advancement compared to available analogical and digital alternatives both in clinical and research contexts for cost reduction, precision and time saving opportunities.

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3