Digital model superimpositions: are different software algorithms equally accurate in quantifying linear tooth movements?

Author:

Adel Samar M.,Vaid Nikhilesh R.,El-Harouni Nadia,Kassem Hassan,Zaher Abbas R.

Abstract

Abstract Background To evaluate the accuracy of three different 3D digital model registration software packages for linear tooth movement measurements, with reference to a 3D digital virtual setup (DS). Methods Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital Setups were generated from pre-treatment scans using OrthoAnalyzer software. Both the pretreatment digital scans (T1) and Digital Setups (T2) were converted to STL files to be imported to the three studied software packages: Geomagic, OrthoAnalyzer and Compare. Linear changes in tooth positions were calculated for all the registered pairs. Results The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the Digital Setups. Continuous data was expressed as mean and standard deviation. Intraclass Correlation Coefficients for agreements between Digital Simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intraclass Correlation Coefficients. Significance of the obtained results was expressed at p ≤ 0.01. Geomagic software showed agreements > 0.90 for maxillary linear tooth movements and between 0.75 and 0.90 for mandibular measurements. OrthoAnalyzer software showed agreements between 0.50 and < 0.75 for maxillary and mandibular measurements. Compare software showed agreements > 0.90 for maxillary and mandibular linear tooth movements, indicating the best consistency. Conclusions Compare and Geomagic software packages consistently showed maximum accuracy in measuring the amount of tooth movement in the maxillary arch compared to the reference standard. Compare software showed the highest agreements in the mandibular arch. None of the three studied software packages showed poor agreement with the Digital Setup across all tooth movement measurements. Buccolingual tooth movements showed the highest agreements amongst linear measurements.

Funder

Alexandria University

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3