Author:
Golshah Amin,Salahshour Mahya,Nikkerdar Nafiseh
Abstract
Abstract
Background
This study aimed to assess the interradicular distance and alveolar bone thickness of Persian adults with different sagittal skeletal patterns for miniscrew insertion using cone-beam computed tomography (CBCT).
Methods
This cross-sectional study was conducted on maxillary and mandibular CBCT scans of 60 patients (18–35 years) in three groups (n = 20) of class I, II and III sagittal skeletal pattern. Anatomical and skeletal parameters were measured at 2, 4 and 6 mm apical to the cementoenamel junction (CEJ) by one examiner. The intra- and inter-class correlation coefficients were calculated to assess the intra, and interobserver reliability. Data were analyzed by ANOVA and Tukey’s test (alpha = 0.05).
Results
The intra- and interobserver reliability were > 0.9 for all parameters. The largest inter-radicular distance in the maxilla was between the central incisors (1–1) in classes I and III, and between premolars (4–5) in class II patients. The largest inter-radicular distance in the mandible was between molar teeth (6–7) in all three classes. The buccal cortical plate thickness was maximum at the site of mandibular first and second molars (6–7). The posterior maxilla and mandible showed the maximum thickness of cancellous bone and alveolar process. Wide variations were noted in this respect between class I, II and III patients.
Conclusions
The area with maximum inter-radicular distance and optimal alveolar bone thickness for miniscrew insertion varies in different individuals, depending on their sagittal skeletal pattern.
Funder
Kermanshah University of Medical Sciences
Publisher
Springer Science and Business Media LLC
Reference36 articles.
1. Pan F, Kau CH, Zhou H, Souccar N. The anatomical evaluation of the dental arches using cone beam computed tomography–an investigation of the availability of bone for placement of mini-screws. Head Face Med. 2013;9:13.
2. Moslemzadeh SH, Sohrabi A, Rafighi A, Kananizadeh Y, Nourizadeh A. Evaluation of interdental spaces of the mandibular posterior area for orthodontic mini-implants with cone-beam computed tomography. J Clin Diagn Res. 2017;11(4):ZC09-ZC12.
3. Kuroda S, Sugawara Y, Deguchi T, Kyung HM, Takano-Yamamoto T. Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort. Am J Orthod Dentofacial Orthop. 2007;131(1):9–15.
4. Schätzle M, Männchen R, Zwahlen M, Lang NP. Survival and failure rates of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res. 2009;20(12):1351–9.
5. Veli I, Uysal T, Baysal A, Karadede I. Buccal cortical bone thickness at miniscrew placement sites in patients with different vertical skeletal patterns. J Orofac Orthop. 2014;75(6):417–29.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献