Digital registration versus cone-beam computed tomography for evaluating implant position: a prospective cohort study

Author:

Han Xinrui,Wei Donghao,Jiang Xi,Di Ping,Yi Chun,Lin Ye

Abstract

Abstract Background Postoperative cone-beam computed tomography (CBCT) examination is considered a reliable method for clinicians to assess the positions of implants. Nevertheless, CBCT has drawbacks involving radiation exposure and high costs. Moreover, the image quality can be affected by artifacts. Recently, some literature has mentioned a digital registration method (DRM) as an alternative to CBCT for evaluating implant positions. The aim of this clinical study was to verify the accuracy of the DRM compared to CBCT scans in postoperative implant positioning. Materials and methods A total of 36 patients who received anterior maxillary implants were included in this clinical study, involving a total of 48 implants. The study included 24 patients in the single implant group and 12 patients in the dual implant group. The postoperative three-dimensional (3D) positions of implants were obtained using both CBCT and DRM. The DRM included three main steps. Firstly, the postoperative 3D data of the dentition and intraoral scan body (ISB) was obtained through the intraoral scan (IOS). Secondly, a virtual model named registration unit which comprised an implant replica and a matching ISB was created with the help of a lab scanner and reverse engineering software. Thirdly, by superimposing the registration unit and IOS data, the postoperative position of the implant was determined. The accuracy of DRM was evaluated by calculating the Root Mean Square (RMS) values after superimposing the implant positions obtained from DRM with those from postoperative CBCT. The accuracy of DRM was compared between the single implant group and the dual implant group using independent sample t-tests. The superimposition deviations of CBCT and IOS were also evaluated. Results The overall mean RMS was 0.29 ± 0.05 mm. The mean RMS was 0.30 ± 0.03 mm in the single implant group and 0.29 ± 0.06 mm in the dual implant group, with no significant difference (p = 0.27). The overall registration accuracy of the IOS and CBCT data ranged from 0.14 ± 0.05 mm to 0.21 ± 0.08 mm. Conclusion In comparison with the 3D implant positions obtained by CBCT, the implant positions located by the DRM showed clinically acceptable deviation ranges. This method can be used in single and dual implant treatments to assess the implant positions.

Funder

Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology

Program for Educational Reform of Peking University School and Hospital of Stomatology

National Central healthcare Research Project

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3