Mechanical activation with Easy Clean device enhanced organic tissue removal from simulated internal root resorption in a laboratory evaluation

Author:

Monteiro Laise Pena BragaORCID,de Sousa Sérgio Emilio Miranda,de Castro Roberta Fonseca,da Silva Emmanuel João Nogueira Leal,da Silva Brandão Juliana Melo

Abstract

Abstract Background Considering the irregular shape of the root canal, removing inflamed pulp and granulation tissue completely from internal resorption cavities during chemomechanical preparation can be challenging. This study aimed to evaluate the effectiveness of passive ultrasonic irrigation (PUI) compared to mechanical activation with Easy Clean in the removal of organic tissue from simulated areas of internal root resorption. Methods The root canals of 72 extracted single-rooted teeth with oval canals were instrumented with Reciproc R25 instruments. After root canal preparations, the specimens were split longitudinally, and semicircular cavities were prepared using a round bur on each half of the roots. Samples obtained from bovine muscle tissue were weighed and adapted into semicircular cavities. The roots were reassembled and joined, and the teeth were divided into six groups (n = 12) according to the irrigation protocol: Sodium hypochlorite (NaOCl) without activation; NaOCl + PUI; NaOCl + Easy Clean; distilled water without activation; distilled water + PUI; and distilled water + Easy Clean. After irrigation protocols, the teeth were disassembled, and the remaining organic tissue was weighed. Data were analyzed by two-way ANOVA and Tukey’s post hoc test (p < 0.05). Results None of the experimental protocols totally removed the bovine tissue from simulated cavities. Tissue weight reduction was significantly affected by the activation method (p < 0.05) and by irrigation solution (p < 0.05). Groups with NaOCl irrigation presented higher tissue weight loss when compared to distilled water, for all irrigation methods (p < 0.05). The use of Easy Clean resulted in the greatest tissue weight loss (42.0%—Distilled water/45.5%- NaOCl) compared to those of PUI (33.3%—Distilled water/37.7%- NaOCl) and no activation (33.4%—Distilled water/38.8%- NaOCl) (p < 0.05). However, no differences were observed between PUI and no activation groups (p > 0.05). Conclusions Mechanical activation with Easy Clean enhanced organic tissue removal from simulated internal resorption more effectively than PUI. Easy Clean for agitation of the irrigating solution is effective in removing simulated organic tissues from artificial internal resorption cavities, being an alternative to the use of PUI.

Funder

Pró-Reitoria de Pesquisa e Pós-Graduação, Universidade Federal do Pará

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3