Background
Two-part abutments are typically made up of a base composed of titanium and a ceramic build-up. The long-term outcomes are affected by the mechanical durability. The purpose of the present investigation was to evaluate and compare the retention force of two-part abutment systems with titanium or titanium nitride bases—as fixed with zirconia components and with various surface treatments.
Methods
A total of 60 two-part abutments were investigated—with a titanium base (n = 30) or titanium nitride coated bases (n = 30) and bonded with zirconia ceramic build-ups. The bonding surfaces were treated with aluminium oxide blasting, with an average particle size of 110 µm. The titanium bases were then pretreated with Alloy Primer or Clearfil Ceramic Primer. The ceramic build-ups were only treated with Clearfil Ceramic Primer. For twenty test specimens, no chemical pretreatment was performed. Test specimens were classified into six groups in accordance with the pretreatment (A–F; n = 10). A resin-based luting agent was employed to attach the two parts. Specimens were then subjected to artificial thermal aging (104 cycles with 5 °C/55 °C). The retention force between the two parts was then investigated with a pull-off test. The findings were analyzed by ANOVA statistics. Fracture patterns were examined by electron microscopy.
Results
In the absence of primer, titanium nitride coated bases gave significantly greater retention forces than other samples (p < 0.05). Chemical preconditioning with silane coupling agents did not effect on the retention force of coated bases.
Conclusions
The results of the current study suggested that modifying metal surfaces by coating the base with titanium nitride not only has esthetic and biological advantages, but also enhances the mechanical properties of the adhesive bond of two-part abutments.
Funder
Medizinische Hochschule Hannover (MHH)
Publisher
Springer Science and Business Media LLC
Reference41 articles.
1. Hamilton A, Judge RB, Palamara JE, Evans C. Evaluation of the fit of CAD/CAM abutments. Int J Prosthodont. 2013;26:370–80.
2. Fuster-Torres MA, Albalat-Estela S, Alcaniz-Raya M, Penarrocha-Diago M. CAD / CAM dental systems in implant dentistry: update. Med Oral Patol Oral Cir Bucal. 2009;14:E141–5.
3. Ioannidis A, Cathomen E, Jung RE, Fehmer V, Husler J, Thoma DS. Discoloration of the mucosa caused by different restorative materials - a spectrophotometric in vitro study. Clin Oral Implants Res. 2017;28:1133–8.
4. Park SE, Da Silva JD, Weber HP, Ishikawa-Nagai S. Optical phenomenon of peri-implant soft tissue. Part I. Spectrophotometric assessment of natural tooth gingiva and peri-implant mucosa. Clin Oral Implants Res. 2007;18:569–74.
5. Hisbergues M, Vendeville S, Vendeville P. Zirconia: Established facts and perspectives for a biomaterial in dental implantology. J Biomed Mater Res B Appl Biomater. 2009;88:519–29.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献