Abstract
Abstract
Background
This in vitro study evaluated the effect of amine-free initiator system and polymerization type on long-term color change of amine-free light-cure and dual-cure resin cements.
Methods
Sixty disk-shaped specimens (10 × 1 mm) were prepared from six different amine-free resin cements; NX3 Nexus light-cure (LC) and dual-cure (DC), Variolink Veneer (LC) and Variolink II (DC), Relyx Veneer (LC) and Rely X Ultimate (DC). A feldspathic porcelain specimen (12 × 14 × 0.8 mm) was obtained from a CAD/CAM block (Cerec Blocks; Sirona Dental Systems GmbH, Bensheim, Germany) for color testing. The feldspathic specimen was placed on the resin cement disk and all measurements were performed without cementation. A spectrophotometer was used for color measurements. Specimens were subjected to thermal aging (5 °C and 55 °C; 5000 and 20,000 cycles). Specific color coordinate differences (ΔL, Δa, and Δb) and the total color differences (ΔE00) were calculated after immersion in distilled water for different periods. Normality of data distribution was tested by using the Kolmogorov–Smirnov test. Data were statistically in a model of repeated measures, using multivariate tests and Tukey’s multiple comparison tests at a significance level of p < 0.05.
Results
∆E00 values of resin cements were influenced by cycle periods, significantly (p < 0.05). The highest ΔE00 values for long term were obtained in the NX3 (DC) (3.49 ± 0.87) and the lowest in the NX3 (LC) (1.41 ± 0.81). NX3 (LC), Variolink (DC), RELY X (LC) resin cements showed clinically acceptable color change after long-term aging (∆E00 < 1.8).
Conclusion
Light-cure resin cements should be preferred for long-term color stability of full ceramic restorations.
Publisher
Springer Science and Business Media LLC
Reference42 articles.
1. Raigrodski AJ, Harrison JD. Esthetic techniques and restorative systems used in the second-year undergraduate dental curriculum. J Esthet Restor Dent. 2003;15(4):233–43.
2. Shiozawa M, Takahashi H, Asakawa Y, Iwasaki N. Color stability of adhesive resin cements after immersion in coffee. Clin Oral Investig. 2015;19(2):309–17.
3. Camacho CE. The effect of delayed light-activation of Variolink II and Calibra dual-cure cements on the shear bond strength of lithium disilicate bonded to dentin Diss. Texas: The University of Texas School of Dentistry at Houston; 2014.
4. Gresnigt M, Özcan M, Muis M, Kalk W. Bonding of glass ceramic and indirect composite to non-aged and aged resin composite. J Adhes Dent. 2012;14(1):59.
5. Van Lierop J. Influence of variations in ceramic thickness and bonding substrate on the fracture resistance of lithium disilicate restorations, 2017.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献