Evaluation of the proximal contact tightness in class II resin composite restorations using different contact forming instruments: a 1-year randomized controlled clinical trial

Author:

Abbassy Karim M.,Elmahy Waleed A.,Holiel Ahmed A.

Abstract

Abstract Background Proper proximal contact in direct composite restorations is crucial for periodontal health. Over a one-year period, this study was conducted to assess successive biological changes in proximal contact tightness PCT in class II direct composite restorations and the adjacent teeth by applying sectional matrix system along with different contact forming instruments. Methods 72 direct compound class II composite restorations were performed in patients aged 18–40 years and divided into 4 groups: Group I (n = 18): proximal contact was restored with Palodent plus sectional matrix system, Group II (n = 18): Trimax as contact forming instrument, Group III (n = 18): Perform as contact forming instrument and Group IV (n = 18): Contact pro as contact forming instrument. All contact forming instruments were used along with Palodent plus matrix system. PCT was measured using a digital force gauge before (T0), immediate post operative (T1) and at 3 (T2), 6 (T3), 9 (T4), and 12 months (T5) after restorative treatment. Using One-Way ANOVA, Tukey’s post hoc test, and Bonferroni correction, PCT values were compared between groups before and after the intervention restoration. Meanwhile, for comparisons within groups, a paired t-test was conducted (p ≤ 0.05). Results Contact forming instruments combined with Palodent plus sectional matrix system achieved better PCT. Trimax led to a statistically considerable tighter proximal contacts than the other groups (p < 0.05). No statistically significant difference was found in PCT between Contact pro-2, Perform and Palodent plus sectional matrix system. By means of multivariate analysis, the PCT between both T0 and T1 were increased (p < 0.001) and then it decreased till T5. Conclusions The use of transparent contact forming instruments achieved greater PCT compared to Palodent sectional matrix system alone that gradually decreased throughout 12 months and reached the PCT between the natural teeth. Using Trimax system provided the tightest proximal contacts. Additionally, digital force gauge was confirmed as an inclusive and accurate method to quantify PCT. Trial registration ClinicalTrials.gov NCT05749640: 24/5/2022.

Funder

Alexandria University

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3