Comparative evaluation of open tray impression technique: investigating the precision of four splinting materials in multiple implants

Author:

Patil Priyanka,Madhav V. N.V,Alshadidi Abdulkhaliq Ali F.,Saini Ravinder S.,Aldosari Lujain Ibrahim N.,Heboyan Artak,Mosaddad Seyed Ali,Bin Hassan Saeed Awod,Chaturvedi Saurabh

Abstract

Abstract Background This study aimed to determine the relative positioning accuracy of multiple implants utilizing four distinct types of splinting materials. Methods The purpose of this in-vitro study was to compare the precision of four splinting materials in an open tray impression technique in multiple implant situations. Based on the material used for splinting, four groups were made (n = 40)- Group A: Conventional Method, Group B: Prefabricated Pattern Resin Framework, Group C: Prefabricated Metal Framework, Group D: Light Cured Pattern Resin, these groups were compared with the master model. A heat-cured clear acrylic resin and a master model were constructed. A pilot milling machine drill was used to drill four parallel holes in the anterior and premolar regions, which were later labeled as A, B, C, and D positions from right to left. Then, sequential drilling was carried out, and four 3.75‑mm diameter and 13-mm long ADIN implant analogs with internal hex were placed in the acrylic model using a surveyor for proper orientation. The impression posts were then manually screwed to the implant analogs using an open tray, and they were secured to the implants using 10 mm flat head guide pins with a 15 N.cm torque. 10 Open tray polyether impressions were made, and casts were poured. Each splinting method’s distortion values were measured using a coordinate measuring machine capable of recordings in the X-, Y-, and Z-axes. Comparison of mean distances for X1, X2, and X3 was made using the Kruskal-Wallis test, and Pairwise comparison was done using Post Hoc Tukey’s Test. Results The differences between the groups were significant when assessing the distances X1, X2, and X3 (p < 0.05). The comparison of deviations between the groups revealed a statistically significant difference (p < 0.05) for the deviation distance X3 but not for the deviation distances X1 and X2. For distance Y1, the difference between the groups was statistically significant (p0.05), but it was not significant for distances Y2 and Y3. A statistically significant difference was seen in the comparison between the groups (p < 0.05) for the deviation distances Y1, Y2, and Y3. The results were statistically significant for the distance Z1 comparisons, namely, control vs. Group A (p = 0.012), control vs. Group B (p = 0.049), control vs. Group C (p = 0.048), and control vs. Group D (p = 0.021), and for distance Z3 comparison for control vs. Group A (p = 0.033). The results were statistically insignificant for the distance Z2 comparisons (p > 0.05). Conclusions All splinting materials produced master casts with measurements in close proximity to the reference model. However, prefabricated pattern resin bars splinting showed the highest accuracy among the studied techniques. The most recent splinting techniques using prefabricated metal framework and light-cure pattern resin showed similar accuracy.

Funder

King Khalid University

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3