Computer-aided design of polyetheretherketone for application to removable pediatric space maintainers

Author:

Guo Hui,Wang Yong,Zhao Yijiao,Liu HeORCID

Abstract

Abstract Background The premature loss of primary teeth is a common problem in pediatric dentistry, resulting in disruption of the arch integrity. Hence, space maintainers (SM) used for maintaining spaces are necessary. However, current methods of making removable space maintainers (RSM) have some limitations. Methods Digital models of dentition defects were obtained by using a scanning technique coupled with laser medical image reconstruction. The digital RSMs were designed using the 3Shape software. They were manufactured using two methods: polyetheretherketone (PEEK), and conventional methods (20 RSMs per group). For qualitative evaluation, the Likert five-point scale was used by 10 experts to obtain a score for 40 RSMs. The spaces between the tissue surfaces of the RSMs and the models were replaced using silicone, and the maximum and mean distances, as well as the standard deviation, were measured. A three-dimensional variation analysis was used to measure these spaces. The student’s t-test and Satterthwaite t-test were used to compare the differences in the spaces for the various materials. Results The PEEK RSMs were found to fit the models well. In the qualitative assessment, the mean experts’ scores for the PEEK and conventional groups were 1.80 ± 0.40 and 1.82 ± 0.40, and there was no significant difference between the two groups (p = 0.875). In the quantitative assessment, the mean spaces for the PEEK digital RSMs and the conventional RSMs were 44.32 ± 1.75 μm, and 137.36 ± 18.63 μm, respectively, and the differences were statistically significant (p < 0.001). In addition, there were significant differences in the maximum space and the standard deviation between the two groups. Conclusion Digitally designed and integrated RSMs were found to be superior to those produced using the conventional method. 3D variation analysis results showed that the mean distances and standard deviations of the PEEK groups were significantly smaller than those of conventional group (p < 0.01). A PEEK-manufactured RSM produced using CAD/CAM would be extremely suitable for clinical applications.

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3