Harmonizing color measurements in dentistry using translucent tooth-colored materials

Author:

Tango Rubens Nisie,Maziero Volpato Claudia Ângela,Santos Karina Félix,Cesar Paulo Francisco,Paravina Rade Dušan

Abstract

Abstract Background Since color measurements are relative, the discrepancy among different instruments is alarmingly high. This multicenter study evaluated the effectiveness of instrument calibration and inter-instrument harmonization of different spectrophotometers with the same optical geometry using tooth-colored, translucent dental materials. Methods The coordinating center (CC) spectrophotometer was calibrated using the NPL Ceram Series II set. Two sets of 10 specimens, labeled 1 to 10 and I to X (10 mm in diameter and 1 mm thick), were tested at CC and three research sites (RS1, RS2, and RS3) using the same d/8° optical geometry spectrophotometers. Calibration factors were calculated for each material and site to obtain the average calibration factors for sets 1–10, set I-X, and the combination of both. The differences among the non-corrected and corrected reflection values were calculated using CIEDE2000 (DeltaE00) and CIELAB (DeltaEab) color difference formulas and were submitted to ANOVA and Tukey test (α = 0.05). Results A significant decrease of color differences between non-corrected as compared to corrected measurements was recorded for all CC-RS and RS-RS comparisons. The reduction of DeltaE00 values between non-corrected and corrected for CC-RS1, CC-RS2, and CC-RS3 were 83.1%, 77.2%, and 73.6%, respectively. The corresponding DeltaE00 values for RS1-RS2, RS1-RS3, and RS2-RS3 comparisons, indirectly compared in the experiment, were 84.2%, 82.8%, and 68.5%, respectively. There was a significant reduction of DeltaE00 and DeltaEab color difference for all combined RS pairs and each of three RS pairs, corrected with one of two specimen sets calibration factors separately. Conclusions Calibration and harmonization of color measurements in dentistry using tooth-colored, translucent restorative materials significantly decreased measurement discrepancies between the coordinating center and research sites and among pairs of research sites.

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3