Accuracy of implant surgical guides fabricated using computer numerical control milling for edentulous jaws: a pilot clinical trial

Author:

Chai Jinyou,Liu Xiaoqian,Schweyen Ramona,Setz Jürgen,Pan ShaoxiaORCID,Liu Jianzhang,Zhou Yongsheng

Abstract

Abstract Background To evaluate the accuracy of a computer numerical control (CNC) milled surgical guide for implant placement in edentulous jaws. Methods Edentulous patients seeking implants treatment were recruited in this prospective cohort study. Radiographic guides with diagnostic templates were fabricated from wax-up dentures. Patients took cone-beam computed tomography (CBCT) wearing the radiopaque radiographic guides. Implant positions were virtually designed in the planning software based on the CBCT data, and the radiographic templates were converted into surgical guides using CNC milling technique. Forty-four implants were placed into 12 edentulous jaws following guided implant surgery protocol. Post-surgery CBCT scans were made for each jaw, and the deviations between the planned and actual implant positions were measured. Deviation of implant position was compared between maxilla and mandible, and between cases with and without anchor pins using independent t-test. Results Nine patients (3 males and 6 females) with 12 edentulous jaws were recruited. The mean age of patients was 59.2 ± 13.9 years old. All 44 implants was placed without complication and survived, the mean three dimensional linear deviation of implant position between virtual planning and actual placement was 1.53 ± 0.48 mm at the implant neck and 1.58 ± 0.49 mm at the apex. The angular deviation was 3.96 ± 3.05 degrees. No significant difference was found in the deviation of implant position between maxilla and mandible (P = 0.28 at neck, 0.08 at apex), nor between cases with and without anchor pins (P = 0.87 at neck, 0.06 at apex). Conclusions The guides fabricated using the CNC milling technique provided comparable accuracy as those fabricated by Stereolithography. The displacement of the guides on edentulous arch might be the main contributing factor of deviation. Trial registration: Chinese Clinical Trial Registry, ChiCTR-ONC-17014159 (July 26, 2017).

Funder

The Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3