The endogenous capacity to produce proinflammatory mediators by the ex vivo human perfused lung
-
Published:2020-09-21
Issue:1
Volume:8
Page:
-
ISSN:2197-425X
-
Container-title:Intensive Care Medicine Experimental
-
language:en
-
Short-container-title:ICMx
Author:
Leligdowicz AleksandraORCID, Ross James T., Nesseler Nicolas, Matthay Michael A.
Abstract
Abstract
Background
The ex vivo human perfused lung model has enabled optimizing donor lungs for transplantation and delineating mechanisms of lung injury. Perfusate and airspace biomarkers are a proxy of the lung response to experimental conditions. However, there is a lack of studies evaluating biomarker kinetics during perfusion and after exposure to stimuli. In this study, we analyzed the ex vivo-perfused lung response to three key perturbations: exposure to the perfusion circuit, exogenous fresh whole blood, and bacteria.
Results
Ninety-nine lungs rejected for transplantation underwent ex vivo perfusion. One hour after reaching experimental conditions, fresh whole blood was added to the perfusate (n = 55). Two hours after reaching target temperature, Streptococcus pneumoniae was added to the perfusate (n = 42) or to the airspaces (n = 17). Perfusate and airspace samples were collected at baseline (once lungs were equilibrated for 1 h, but before blood or bacteria were added) and 4 h later. Interleukin (IL)-6, IL-8, angiopoietin (Ang)-2, and soluble tumor necrosis factor receptor (sTNFR)-1 were quantified. Baseline perfusate and airspace biomarker levels varied significantly, and this was not related to pre-procurement PaO2:FiO2 ratio, cold ischemia time, and baseline alveolar fluid clearance (AFC). After 4 h of ex vivo perfusion, the lung demonstrated a sustained production of proinflammatory mediators. The change in biomarker levels was not influenced by baseline donor lung characteristics (cold ischemia time, baseline AFC) nor was it associated with measures of experimental epithelial (final AFC) or endothelial (percent weight gain) injury. In the presence of exogenous blood, the rise in biomarkers was attenuated. Lungs exposed to intravenous (IV) bacteria relative to control lungs demonstrated a significantly higher rise in perfusate IL-6.
Conclusions
The ex vivo-perfused lung has a marked endogenous capacity to produce inflammatory mediators over the course of short-term perfusion that is not significantly influenced by donor lung characteristics or the presence of exogenous blood, and only minimally affected by the introduction of systemic bacteremia. The lack of association between biomarker change and donor lung cold ischemia time, final alveolar fluid clearance, and experimental percent weight gain suggests that the maintained ability of the human lung to produce biomarkers is not merely a marker of lung epithelial or endothelial injury, but may support the function of the lung as an immune cell reservoir.
Funder
Canadian Institutes of Health Research University of Toronto Clinician Scientist Training Program National Institutes of Health Société Française d’Anesthésie-Réanimation Association Chirurgicale pour le Développement et l’Amélioration des Techniques de Dépistage de Traitement des Maladies Cardiovasculaires Journées Rennaises d’Anesthésie-Réanimation (JRAR) association
Publisher
Springer Science and Business Media LLC
Subject
Critical Care and Intensive Care Medicine
Reference45 articles.
1. Ross JT, Nesseler N, Lee JW, Ware LB, Matthay MA (2019) The ex vivo human lung: research value for translational science. JCI Insight 4(11):e128833 2. Ware LB, Wang Y, Fang X, Warnock M, Sakuma T, Hall TS, Matthay M (2002) Assessment of lungs rejected for transplantation and implications for donor selection. Lancet 360:619–620 3. Frank JA, Briot R, Lee JW, Ishizaka A, Uchida T, Matthay MA (2007) Physiological and biochemical markers of alveolar epithelial barrier dysfunction in human perfused lungs. Am J Physiol Lung Cell Mol Physiol 293:L52–L59 4. Fisher A, Andreasson A, Chrysos A, Lally J, Mamasoula C, Exley C, Wilkinson J, Qian J, Watson G, Lewington O, Chadwick T, McColl E, Pearce M, Mann K, McMeekin N, Vale L, Tsui S, Yonan N, Simon A, Marczin N, Mascaro J, Dark J (2016) An observational study of Donor Ex Vivo Lung Perfusion in UK lung transplantation: DEVELOP-UK. Health Technol Assess 20:1–276 5. Cypel M, Yeung JC, Liu M, Anraku M, Chen F, Karolak W, Sato M, Laratta J, Azad S, Madonik M, Chow CW, Chaparro C, Hutcheon M, Singer LG, Slutsky AS, Yasufuku K, de Perrot M, Pierre AF, Waddell TK, Keshavjee S (2011) Normothermic ex vivo lung perfusion in clinical lung transplantation. N Engl J Med 364:1431–1440
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|