Continuous monitoring of left ventricular function in postoperative intensive care patients using artificial intelligence and transesophageal echocardiography

Author:

Yu JinyangORCID,Taskén Anders Austlid,Berg Erik Andreas Rye,Tannvik Tomas Dybos,Slagsvold Katrine Hordnes,Kirkeby-Garstad Idar,Grenne Bjørnar,Kiss Gabriel,Aakhus Svend

Abstract

Abstract Background Continuous monitoring of mitral annular plane systolic excursion (MAPSE) using transesophageal echocardiography (TEE) may improve the evaluation of left ventricular (LV) function in postoperative intensive care patients. We aimed to assess the utility of continuous monitoring of LV function using TEE and artificial intelligence (autoMAPSE) in postoperative intensive care patients. Methods In this prospective observational study, we monitored 50 postoperative intensive care patients for 120 min immediately after cardiac surgery. We recorded a set of two-chamber and four-chamber TEE images every five minutes. We defined monitoring feasibility as how often the same wall from the same patient could be reassessed, and categorized monitoring feasibility as excellent if the same LV wall could be reassessed in ≥ 90% of the total recordings. To compare autoMAPSE with manual measurements, we rapidly recorded three sets of repeated images to assess precision (least significant change), bias, and limits of agreement (LOA). To assess the ability to identify changes (trending ability), we compared changes in autoMAPSE with the changes in manual measurements in images obtained during the initiation of cardiopulmonary bypass as well as before and after surgery. Results Monitoring feasibility was excellent in most patients (88%). Compared with manual measurements, autoMAPSE was more precise (least significant change 2.2 vs 3.1 mm, P < 0.001), had low bias (0.4 mm), and acceptable agreement (LOA − 2.7 to 3.5 mm). AutoMAPSE had excellent trending ability, as its measurements changed in the same direction as manual measurements (concordance rate 96%). Conclusion Continuous monitoring of LV function was feasible using autoMAPSE. Compared with manual measurements, autoMAPSE had excellent trending ability, low bias, acceptable agreement, and was more precise. Graphical Abstract

Funder

Helse Midt-Norge

NTNU Norwegian University of Science and Technology

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3