Dynamic changes of hepatic vein Doppler velocities predict preload responsiveness in mechanically ventilated critically ill patients

Author:

Bruna Mario,Alfaro Sebastian,Muñoz Felipe,Cisternas Liliana,Gonzalez Cecilia,Conlledo Rodrigo,Ulloa-Morrison Rodrigo,Huilcaman Marcos,Retamal Jaime,Castro Ricardo,Rola Philippe,Wong Adrian,Argaiz Eduardo R.,Contreras Roberto,Hernandez Glenn,Kattan EduardoORCID

Abstract

Abstract Background Assessment of dynamic parameters to guide fluid administration is one of the mainstays of current resuscitation strategies. Each test has its own limitations, but passive leg raising (PLR) has emerged as one of the most versatile preload responsiveness tests. However, it requires real-time cardiac output (CO) measurement either through advanced monitoring devices, which are not routinely available, or echocardiography, which is not always feasible. Analysis of the hepatic vein Doppler waveform change, a simpler ultrasound-based assessment, during a dynamic test such as PLR could be useful in predicting preload responsiveness. The objective of this study was to assess the diagnostic accuracy of hepatic vein Doppler S and D-wave velocities during PLR as a predictor of preload responsiveness. Methods Prospective observational study conducted in two medical–surgical ICUs in Chile. Patients in circulatory failure and connected to controlled mechanical ventilation were included from August to December 2023. A baseline ultrasound assessment of cardiac function was performed. Then, simultaneously, ultrasound measurements of hepatic vein Doppler S and D waves and cardiac output by continuous pulse contour analysis device were performed during a PLR maneuver. Results Thirty-seven patients were analyzed. 63% of the patients were preload responsive defined by a 10% increase in CO after passive leg raising. A 20% increase in the maximum S wave velocity after PLR showed the best diagnostic accuracy with a sensitivity of 69.6% (49.1–84.4) and specificity of 92.8 (68.5–99.6) to detect preload responsiveness, with an area under curve of receiving operator characteristic (AUC–ROC) of 0.82 ± 0.07 (p = 0.001 vs. AUC–ROC of 0.5). D-wave velocities showed worse diagnostic accuracy. Conclusions Hepatic vein Doppler assessment emerges as a novel complementary technique with adequate predictive capacity to identify preload responsiveness in patients in mechanical ventilation and circulatory failure. This technique could become valuable in scenarios of basic hemodynamic monitoring and when echocardiography is not feasible. Future studies should confirm these results.

Funder

Agencia Nacional de Investigación y Desarrollo

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3