Standard versus individualised positive end-expiratory pressure (PEEP) compared by electrical impedance tomography in neurocritical care: a pilot prospective single centre study

Author:

Spatenkova VeraORCID,Mlcek Mikulas,Mejstrik Alan,Cisar Lukas,Kuriscak Eduard

Abstract

Abstract Background Individualised bedside adjustment of mechanical ventilation is a standard strategy in acute coma neurocritical care patients. This involves customising positive end-expiratory pressure (PEEP), which could improve ventilation homogeneity and arterial oxygenation. This study aimed to determine whether PEEP titrated by electrical impedance tomography (EIT) results in different lung ventilation homogeneity when compared to standard PEEP of 5 cmH2O in mechanically ventilated patients with healthy lungs. Methods In this prospective single-centre study, we evaluated 55 acute adult neurocritical care patients starting controlled ventilation with PEEPs close to 5 cmH2O. Next, the optimal PEEP was identified by EIT-guided decremental PEEP titration, probing PEEP levels between 9 and 2 cmH2O and finding the minimal amount of collapse and overdistension. EIT-derived parameters of ventilation homogeneity were evaluated before and after the PEEP titration and after the adjustment of PEEP to its optimal value. Non-EIT-based parameters, such as peripheral capillary Hb saturation (SpO2) and end-tidal pressure of CO2, were recorded hourly and analysed before PEEP titration and after PEEP adjustment. Results The mean PEEP value before titration was 4.75 ± 0.94 cmH2O (ranging from 3 to max 8 cmH2O), 4.29 ± 1.24 cmH2O after titration and before PEEP adjustment, and 4.26 ± 1.5 cmH2O after PEEP adjustment. No statistically significant differences in ventilation homogeneity were observed due to the adjustment of PEEP found by PEEP titration. We also found non-significant changes in non-EIT-based parameters following the PEEP titration and subsequent PEEP adjustment, except for the mean arterial pressure, which dropped statistically significantly (with a mean difference of 3.2 mmHg, 95% CI 0.45 to 6.0 cmH2O, p < 0.001). Conclusion Adjusting PEEP to values derived from PEEP titration guided by EIT does not provide any significant changes in ventilation homogeneity as assessed by EIT to ventilated patients with healthy lungs, provided the change in PEEP does not exceed three cmH2O. Thus, a reduction in PEEP determined through PEEP titration that is not greater than 3 cmH2O from an initial value of 5 cmH2O is unlikely to affect ventilation homogeneity significantly, which could benefit mechanically ventilated neurocritical care patients.

Funder

TACR

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3