Five-year outcomes of EVO implantable collamer lens implantation for the correction of high myopia and super high myopia

Author:

Chen Xun,Wang Xuanqi,Xu Yilin,Cheng Mingrui,Han Tian,Niu LingLing,Wang XiaoyingORCID,Zhou Xingtao

Abstract

Abstract Background To evaluate the long-term safety, efficacy, predictability, and stability of implantable collamer lens with a central hole (EVO ICL) implantation for correcting high myopia (HM) and super high myopia (SHM). Methods This prospective study evaluated 83 eyes of 46 patients who were divided into groups based on their spherical equivalent refractive error (SE): HM group (− 12 D ≤ SE < − 6 D) and SHM group (SE < − 12 D). They were followed up for 5 years after ICL implantation; assessments of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refractive error, axial length, intraocular pressure, corneal endothelial cell density, and vault were conducted, and a questionnaire was administered. ResuIts At 5 years postoperatively, the safety indices of the HM and SHM groups were 1.03 ± 0.10 and 1.32 ± 0.39, and the efficacy indices were 0.83 ± 0.25 and 0.86 ± 0.32, respectively. In the HM group, 60.47% and 79.07% of the eyes were within ± 0.50 D and ± 1.00 D of the attempted correction, while it was achieved for 22.50% and 47.50% of the eyes in the SHM group, respectively. The SE of the HM group decreased from  − 9.72 ± 1.41 D preoperatively to 0.04 ± 0.39 D 1 month postoperatively and − 0.67 ± 0.57 D 5 years postoperatively, while in the SHM group, it decreased from − 15.78 ± 3.06 D preoperatively to  − 0.69 ± 0.97 D 1 month postoperatively and − 1.74 ± 1.19 D 5 years postoperatively. Conclusion EVO ICL implantation is safe, effective, and predictable for correcting HM and SHM. CDVA improved more after surgery for SHM, but the growth of axial length still needs attention.

Funder

National Natural Science Foundation of China

Joint research project of new frontier technology in municipal hospitals

Project of Shanghai Science and Technology

Major clinical research project of Shanghai Shenkang Hospital Development Center

Project of Shanghai Xuhui District Science and Technology

Shanghai Science and Technology Commission

Publisher

Springer Science and Business Media LLC

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3