Abstract
Abstract
Purpose
To evaluate the refractive prediction error of common intraocular lens (IOL) power calculation formulae in patients who underwent intrascleral IOL fixation using two different techniques.
Methods
This is a prospective, randomized, longitudinal, single-site, single-surgeon study. Patients who underwent intrascleral IOL implantation using the Yamane or the Carlevale technique were followed up for a period of six months postoperatively. Refraction was measured using the best-corrected visual acuity at 4 m (EDTRS chart). Lens decentration, tilt and effective lens position (ELP) were assessed using an anterior segment optical coherence tomography (AS-OCT). The prediction error (PE) and the absolute error (AE) were evaluated for the SRK/T, Hollayday1 and Hoffer Q formula. Subsequently, correlations between the PE and axial length, keratometry, white to white and ELP were assessed.
Results
In total, 53 eyes of 53 patients were included in the study. Twenty-four eyes of 24 patients were in the Yamane group (YG) and 29 eyes of 29 patients were in the Carlevale group (CG). In the YG, the Holladay 1 and Hoffer Q formulae resulted in a hyperopic PE (0.02 ± 0.56 D, and 0.13 ± 0.64 D, respectively) while in the SRK/T formula the PE was slightly myopic (− 0.16 ± 0.56 D). In the CG, SRK/T and Holladay 1 formulae led to a myopic PE (− 0.1 ± 0.80 D and − 0.04 ± 0.74 D, respectively), Hoffer Q to a hyperopic PE (0.04 ± 0.75 D). There was no difference between the PE of the same formulae across both groups (P > 0.05).
In both groups the AE differed significantly from zero in each evaluated formula. The AE error was within ± 0.50 D in 45%–71% and was within ± 1.00 D in 72%–92% of eyes depending on the formula and surgical method used. No significant differences were found between formulae within and across groups (P > 0.05). Intraocular lens tilt was lower in the CG (6.45 ± 2.03°) compared to the YG (7.67 ± 3.70°) (P < 0.001). Lens decentration was higher in the YG (0.57 ± 0.37 mm) than in the CG (0.38 ± 0.21 mm), though the difference was not statistically significant (P = 0.9996).
Conclusions
Refractive predictability was similar in both groups. IOL tilt was better in the CG, however this did not influence the refractive predictability. Though not significant, Holladay 1 formula seemed to be more probable than the SRK/T and Hoffer Q formulae. However, significant outliers were observed in all three different formulae and therefore remain a challenging task in secondary fixated IOLs.
Publisher
Springer Science and Business Media LLC
Subject
Ophthalmology,Health Professions (miscellaneous)
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献