Comparison of Ex-PRESS implantation versus trabeculectomy combined with phacoemulsification in primary open-angle glaucoma: a retrospective in vivo confocal microscopy study

Author:

Zhang Yuqiao,He Beiting,Zhang Yulin,Zeng Jin,Chen Yanlei,Niu Yongyi,Yu Honghua,Qin Yongjie,Zhang HongyangORCID

Abstract

Abstract Background To compare the efficacy of Ex-PRESS implantation versus trabeculectomy combined with phacoemulsification. Methods A retrospective 12-month study on patients with coincident primary open-angle glaucoma (POAG) and cataract. The patients underwent combined phacoemulsification and Ex-PRESS implant (Phaco-ExPRESS, n = 35) or phacotrabeculectomy (Phaco-Trab, n = 35). The morphological structures of the filtering bleb were examined by slit-lamp, anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). Complete success was defined as postoperative intraocular pressure (IOP) < 18 mmHg without the use of anti-glaucoma medication. Qualified success was defined as postoperative IOP < 18 mmHg with or without anti-glaucoma medications. The data were collected preoperatively and postoperatively at 2 weeks, 1 month, 3 months, 6 months, and 12 months. Results No significant difference in the variables such as age, IOP and perimetry was found between the groups of Phaco-ExPRESS and Phaco-Trab. At the one-year postoperative visit for filtering blebs, Phaco-ExPRESS increased the mean area of epithelial microcysts significantly from 0.10 ± 0.05 to 0.20 ± 0.09 μm2 per μm2, while Phaco-Trab decreased the mean area significantly from 0.08 ± 0.04 to 0.04 ± 0.06 μm2 per μm2. Notably, the hyperreflective dots detected by IVCM decreased by 84.9% in Phaco-ExPRESS but increased by 36.3% in Phaco-Trab. The hyperreflective dots were further identified as neutrophil- and monocyte-like cells. The number of these cells were negatively correlated with the microcysts area (r =  − 0.7, P < 0.01) but positively associated with the grade of connective tissue (r = 0.5, P < 0.01). By creating different microstructural changes in the filtering blebs, Phaco-ExPRESS produced a higher complete success rate (84.9% vs. 41.2%, P < 0.01) and significant decrease in the number of anti-glaucoma medications (P < 0.01) when compared with those in Phaco-Trab. However, the qualified success showed no significant difference between the two groups (100.0% vs. 91.2%, P = 0.24). Conclusions At the one-year follow-up, Phaco-ExPRESS generated better filtering bleb with larger area of microcysts, looser connective tissues, and less inflammation than that of Phaco-Trab, providing adequate IOP control and less IOP-lowering medications. These findings indicate that Phaco-ExPRESS could be more preferred than Phaco-Trab for the treatment of patients with coincident POAG and cataract.

Funder

natural science foundation of guangdong province

Publisher

Springer Science and Business Media LLC

Subject

General Earth and Planetary Sciences,General Environmental Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3