Abstract
Abstract
Background
To assess the multicenter outcomes of posterior chamber phakic intraocular lens implantation with a central hole (EVO-ICL, STAAR Surgical) for patients undergoing previous laser in situ keratomileusis (LASIK).
Methods
This case series enrolled 31 eyes of 21 consecutive patients undergoing EVO-ICL implantation to correct residual refractive errors after LASIK at 7 nationwide major surgical sites. We investigated safety, efficacy, predictability, stability, and adverse events at 1 week, 1, 3, and 6 months postoperatively, and at the final visit.
Results
The mean observation period was 1.6 ± 1.8 years. Uncorrected and corrected visual acuities were − 0.14 ± 0.11 and − 0.22 ± 0.09 logMAR at 6 months postoperatively. At 6 months postoperatively, 81% and 100% of eyes were within ± 0.5 D and ± 1.0 D, respectively, of the targeted correction. We found neither significant manifest refraction changes of 0.05 ± 0.38 D from 1 week to 6 months nor apparent intraoperative or postoperative complications in any case.
Conclusions
Our multicenter study confirmed that the EVO-ICL provided good outcomes in safety, efficacy, predictability, and stability, even in post-LASIK eyes. Therefore, EVO-ICL implantation may be a viable surgical option, even for correcting residual refractive errors after LASIK.
Trial registration University Hospital Medical Information Network Clinical Trial Registry (000045295).
Publisher
Springer Science and Business Media LLC
Subject
General Earth and Planetary Sciences,General Environmental Science
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献