Can the bias of self-reported sitting time be corrected? A statistical model validation study based on data from 23 993 adults in the Norwegian HUNT study

Author:

Kongsvold AtleORCID,Flaaten Mats,Logacjov Aleksej,Skarpsno Eivind Schjelderup,Bach Kerstin,Nilsen Tom Ivar Lund,Mork Paul Jarle

Abstract

Abstract Background Despite apparent shortcomings such as measurement error and low precision, self-reported sedentary time is still widely used in surveillance and research. The aim of this study was threefold; (i) to examine the agreement between self-reported and device-measured sitting time in a general adult population; (ii), to examine to what extent demographics, lifestyle factors, long-term health conditions, physical work demands, and educational level is associated with measurement bias; and (iii), to explore whether correcting for factors associated with bias improves the prediction of device-measured sitting time based on self-reported sitting time. Methods A statistical validation model study based on data from 23 993 adults in the Trøndelag Health Study (HUNT4), Norway. Participants reported usual sitting time on weekdays using a single-item questionnaire and wore two AX3 tri-axial accelerometers on the thigh and low back for an average of 3.8 (standard deviation [SD] 0.7, range 1–5) weekdays to determine their sitting time. Statistical validation was performed by iteratively adding all possible combinations of factors associated with bias between self-reported and device-measured sitting time in a multivariate linear regression. We randomly selected 2/3 of the data (n = 15 995) for model development and used the remaining 1/3 (n = 7 998) to evaluate the model. Results Mean (SD) self-reported and device-measured sitting time were 6.8 (2.9) h/day and 8.6 (2.2) h/day, respectively, corresponding to a mean difference of 1.8 (3.1) h/day. Limits of agreement ranged from − 8.0 h/day to 4.4 h/day. The discrepancy between the measurements was characterized by a proportional bias with participants device-measured to sit less overestimating their sitting time and participants device-measured to sit more underestimating their sitting time. The crude explained variance of device-measured sitting time based on self-reported sitting time was 10%. This improved to 24% when adding age, body mass index and physical work demands to the model. Adding sex, lifestyle factors, educational level, and long-term health conditions to the model did not improve the explained variance. Conclusions Self-reported sitting time had low validity and including a range of factors associated with bias in self-reported sitting time only marginally improved the prediction of device-measured sitting time.

Funder

NTNU Norwegian University of Science and Technology

Publisher

Springer Science and Business Media LLC

Subject

Nutrition and Dietetics,Physical Therapy, Sports Therapy and Rehabilitation,Medicine (miscellaneous)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3